Spring Sale Special Limited Time 70% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: buysanta

Exact2Pass Menu

Installing and Configuring a Blue Prism (Version 6.0) Environment (EN)

Last Update 12 hours ago Total Questions : 45

The Installing and Configuring a Blue Prism (Version 6.0) Environment (EN) content is now fully updated, with all current exam questions added 12 hours ago. Deciding to include AIE02 practice exam questions in your study plan goes far beyond basic test preparation.

You'll find that our AIE02 exam questions frequently feature detailed scenarios and practical problem-solving exercises that directly mirror industry challenges. Engaging with these AIE02 sample sets allows you to effectively manage your time and pace yourself, giving you the ability to finish any Installing and Configuring a Blue Prism (Version 6.0) Environment (EN) practice test comfortably within the allotted time.

Question # 11

Which of the following reasons would prevent the Blue Prism Server service from being started? (Select four.)

A.

If it can’t find a BPServer.exe profile with the name that is expects

B.

If the BPServer.exe profile is not configured with the expected encryption schemes

C.

If the user that the server is attempting to use cannot access the Blue Prism database

D.

If there are no Blue Prism devices configured to connect to the server service

E.

There is a problem with the Blue Prism license key in the environment

F.

If the server service has nothing to process (e.g. if there are no schedules configured)

Question # 12

Which of the following are steps that would normally be take on the local device when configuring a Runtime Resource? (Select four.)

A.

Configure a connection to a Blue Prism Application Server

B.

Configure the database maintenance procedures

C.

Configure the Runtime Resource to start automatically when the device is logged on with appropriate parameters

D.

Optionally configure the Runtime Resource start-up procedure with the thumbprint of a local certificate

E.

Optionally install and configure Login Agent

F.

Ensure the AutomateC.exe is accessible to the logged in user

G.

Disable all domain policies

Question # 13

When a Runtime Resource has been started using the /sslcert switch, why might it not be able to receive connections? (Select three.)

A.

If the name on the certificate does not match the name being used to connect to the Runtime Resource

B.

If the thumbprint of the certificate is not for a valid certificate on the local device

C.

If the certificate has expired or been revoked

D.

If the certificate has not been issued by a certification authority that is trusted by the device attempting to connect

E.

If the context user of the Runtime Resource does not have read-only access to the certificate’s private key

Go to page: