You'll find that our CTS-I exam questions frequently feature detailed scenarios and practical problem-solving exercises that directly mirror industry challenges. Engaging with these CTS-I sample sets allows you to effectively manage your time and pace yourself, giving you the ability to finish any Certified Technology Specialist – Installation practice test comfortably within the allotted time.

Question # 41

Determine the wattage in a circuit measuring 120 volts with 15 amperes of current flow.

A.

80W

B.

0.125W

C.

1800W

D.

8W

Question # 42

Which of the following is one possible covering for twisted pair cable?

A.

Rubber

B.

Copper

C.

Wood

D.

Mercerized cotton

Question # 43

A ____ is an electrical problem that has two points of failure.

A.

Ground-fault current path

B.

Short

C.

Ground-fault

D.

Line-to-ground

Question # 44

Which set of drawings should you reference to view the ductwork that goes through the building?

A.

Architectural drawings

B.

Mechanical drawings

C.

System drawings

D.

Electrical drawings

Question # 45

Place a cable label on ____ of every cable.

A.

the cable jacket on the load end

B.

the cable jacket of the source end

C.

every connector

D.

both ends of the cable jacket

Question # 46

Why is it better to test control systems in the workshop? (Choose all that apply.)

A.

It allows more time to fix problems.

B.

It may provide better access to help from internal teams.

C.

It allows time for longer breaks.

D.

It prevents customers from asking questions.

Question # 47

An RG59 coaxial SDI cable with an outer diameter of 6 millimeters (0.24 inches) is being installed in a conduit, along with four Cat 6A UTP data cables with an outer diameter of 8 millimeters (0.32 inches). If the allowable fill percentage for conduit with three or more cables in the region is 40 percent, what is the minimum inner diameter of the conduit?

A.

44 millimeters (1.75 inches)

B.

33 millimeters (1.28 inches)

C.

27 millimeters (1.06 inches)

D.

60 millimeters (2.38 inches)

Question # 48

Punch block termination works with _____.

A.

linear compression

B.

soldering

C.

crimping

D.

insulation displacement

Question # 49

What is the function of a back box?

A.

It keeps sound contained into a single room

B.

It transmits sound to adjoining areas through the ceiling space

C.

It limits the low frequency response of the loudspeaker

D.

It helps hold the wires stable as you crimp butt splices onto them

Question # 50

In an electrical power distribution installation, the safety earth/ground connects to: (Choose all that apply.)

A.

the ground (planet Earth)

B.

raceways, ducts, conduit, and cable trays

C.

exposed conductive parts of the installation

D.

equipment racks