Spring Sale Special Limited Time 70% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: buysanta

Exact2Pass Menu

Specialist - Technology Architect. PowerMax and VMAX All Flash Solutions Exam

Last Update 11 hours ago Total Questions : 60

The Specialist - Technology Architect. PowerMax and VMAX All Flash Solutions Exam content is now fully updated, with all current exam questions added 11 hours ago. Deciding to include DES-1111 practice exam questions in your study plan goes far beyond basic test preparation.

You'll find that our DES-1111 exam questions frequently feature detailed scenarios and practical problem-solving exercises that directly mirror industry challenges. Engaging with these DES-1111 sample sets allows you to effectively manage your time and pace yourself, giving you the ability to finish any Specialist - Technology Architect. PowerMax and VMAX All Flash Solutions Exam practice test comfortably within the allotted time.

Question # 1

What is a Composite Group in BCSD?

A.

Collection of SRDF physical relationships

B.

Collection of SRDF logical relationships

C.

Collection of MSC physical relationships

D.

Collection of Replication Groups

Question # 2

Refer to the exhibit.

An SRDF/A solution with BCSD is designed and the results are shown in the exhibit. A customer requirement was a five-minute RPO. In the exhibit shown, the RPO is above the customer requirement.

How can the five-minute RPO requirement be met?

A.

Increase DSE capacity

B.

Provide more bandwidth

C.

Increase number of RA ports

D.

Increase cycle time

Question # 3

A PowerMax Storage Group has Host I/O limits set at 10000 IOPS. The Port Group contains four ports across different directors. The Dynamic Distribution is set to OnFailure.

What is the maximum IOPS the Storage Group can achieve in the event a switch port being used by one of the director ports fails but the director remains online?

A.

2500

B.

5000

C.

7500

D.

10000

Question # 4

What method is used to collect host-based performance data for Windows hosts with BCSD?

A.

SAR

B.

IOSTAT

C.

MMC

D.

PERFMON

Question # 5

Refer to the exhibit.

This performance data is an example of what of output?

A.

PERFMON

B.

SAR

C.

ESXTOP

D.

IOSTAT

Question # 6

A data migration is being planned from a Hitachi to a PowerMax using Open Replicator. Which flag is used to protect against SAN failure?

A.

Background Copy

B.

Donor Update

C.

Copy on Access

D.

Hot Push

Question # 7

An architect uses the following command to collect data from a HP-UX host when designing a solution in BCSD:

sar –d –b interval count > > hostname.sar.date.txt

What does the –b flag in the command represent?

A.

Block

B.

Binary

C.

Break

D.

Buffer

Question # 8

What is the default data collection interval for TTP collections?

A.

5 minutes

B.

10 minutes

C.

15 minutes

D.

30 minutes

Question # 9

What happens to the space used for SnapVX delta tracks that are unique to a terminated snapshot?

A.

Not returned to SRP until the –force fag is used

B.

Not returned to SRP until all generations are terminated

C.

Returned to SRP only if it is mentioned explicitly

D.

Returned to the SRP by default

Question # 10

A storage architect is looking for best practices to expand an existing single V-Brick VMAX All Flash 250. They are planning to expand the VMAX configuration to a dual V-Brick model for better performance.

What is a consideration?

A.

Both V-Bricks must contain 1 TB of cache each

B.

RAID type of both V-Bricks must be the same

C.

Cache size of both V-Bricks must be equal

D.

Number of drives must be less than or equal to 96

Go to page: