67 - Fire Inspector II Exam

Last Update 5 hours ago Total Questions : 87

The 67 - Fire Inspector II Exam content is now fully updated, with all current exam questions added 5 hours ago. Deciding to include Fire-Inspector-II practice exam questions in your study plan goes far beyond basic test preparation.

You'll find that our Fire-Inspector-II exam questions frequently feature detailed scenarios and practical problem-solving exercises that directly mirror industry challenges. Engaging with these Fire-Inspector-II sample sets allows you to effectively manage your time and pace yourself, giving you the ability to finish any 67 - Fire Inspector II Exam practice test comfortably within the allotted time.

Question # 11

Panic hardware is required on exit doors serving an occupant load of __ or more in a Group __ Occupancy

A.

10; A

B.

50; A

C.

50; M

D.

100; F

Question # 12

At each grinding, buffing, or wire brushing operation on magnesium, other than the rough finishing of casting, dust must be collected by means of suitable hoods or enclosures connected to a:

A.

cloth screen arrestor.

B.

low-pressure cyclone.

C.

dry-type dynamic precipitator.

D.

liquid precipitation type of separator.

Question # 13

Given: A local college student inquires about the use of candles in their dorm room. Candles:

A.

may not be used.

B.

may be used in a sprinklered dormitory.

C.

must be kept a minimum 12 in. from combustibles.

D.

must be kept a minimum 36 in. from combustibles.

Question # 14

Given: In organic coating processes where Class I liquids are exposed to the air, Class I, Division I electrical installations are required to be outside the immediate vicinity of pumps or equipment.

" Immediate vicinity " means in addition to a vertical distance a zone extending from the vapor liberation point __ ft. horizontally in all directions.

A.

5

B.

10

C.

20

D.

50

Question # 15

The minimum allowable distance to a public traffic route for storage of 1,750 lb. of Class 1.3 explosives is ___ ft.

A.

50

B.

75

C.

115

D.

150

Question # 16

One or more approved fire extinguishers must be located within __ ft. of hot work locations.

A.

20

B.

30

C.

40

D.

50

Question # 17

Two tents which each have an area of 20,000 sq. ft. shall be separated from each other by a distance of not less than:

A.

0 ft. (no separation is required).

B.

10 ft.

C.

20 ft.

D.

25 ft.

Question # 18

A bowling center with 25 lanes and 3,500 sq. ft. of additional area calculates to a maximum occupant load of how many people?

A.

125

B.

234

C.

500

D.

625

Question # 19

The minimum fire-flow for a 75,000-sq. ft. building of Type IIB construction without a sprinkler system is:

A.

3,000 gpm for 3 hours.

B.

4,000 gpm for 4 hours.

C.

5,500 gpm for 4 hours.

D.

5,750 gpm for 4 hours.

Question # 20

A local board of appeals may perform all of the following functions except:

A.

waive requirements of the fire code.

B.

render interpretations of the fire code.

C.

approve alternate materials and types of construction.

D.

adopt rules and regulations for conducting its investigations.

Go to page: