HCIP-Data Center Facility Deployment V2.0

Last Update 10 hours ago Total Questions : 55

The HCIP-Data Center Facility Deployment V2.0 content is now fully updated, with all current exam questions added 10 hours ago. Deciding to include H12-425_V2.0 practice exam questions in your study plan goes far beyond basic test preparation.

You'll find that our H12-425_V2.0 exam questions frequently feature detailed scenarios and practical problem-solving exercises that directly mirror industry challenges. Engaging with these H12-425_V2.0 sample sets allows you to effectively manage your time and pace yourself, giving you the ability to finish any HCIP-Data Center Facility Deployment V2.0 practice test comfortably within the allotted time.

Question # 1

In a project 32 NetCol8000-Cs need to be networked for teamwork. Each group consists of four air conditioners. How should the northbound RS485 grouping switches, namely, toggle switches 2 and 3 on the main control module, be set for the last air conditioner in each group?

A.

ON, ON

B.

ON, OFF

C.

OFF, ON

D.

OFF, OFF

Question # 2

Which of the following are components of NetCol8000-E220? (Choose three.)

A.

Indirect heat exchange system

B.

Mechanical auxiliary cooling system

C.

Spray system

D.

Electric control system

Question # 3

Which features of Huawei integrated UPS can reduce the footprint?

A.

Intelligent alternating hibernation technology

B.

High power density design

C.

Hot swap

D.

Installation against a wall

Question # 4

During filling refrigerant for NetCol5000-A, there is no need to put the refrigerant steel cylinder upside down on balance.

A.

True

B.

False

Question # 5

Which of the following actions may be triggered after the high liquid level float of a Huawei chilled water precision air conditioner floats longer than the specified duration?

A.

The air conditioner shuts down.

B.

One water pump starts.

C.

A drainage exception alarm is generated.

D.

One water pump shuts down.

Question # 6

Which of the following position is recommended for installing the smart ETH gateway?

A.

Control skylight

B.

Inside a network cabinet

C.

At the inner side of a door header

D.

At the side of a cable trough

Question # 7

The ECC800-Pro is the core component for FusionModule2000 local management. Southbound components can be using the PoE bus.

A.

True

B.

False

Question # 8

Which of the following methods can be used to open the access control for the FusionModule2000 smart module?

A.

Fingerprint

B.

Card reader

C.

Password

D.

Facial recognition

Question # 9

Which air supply mode requires reasonable raised floor height?

A.

Air supply mode using blast caps.

B.

Underfloor air supply mode

C.

Air supply mode using wind pipe

D.

In-row horizontal air supply mode

Question # 10

In the FusionModule800 grounding solution, each cabinet is connected to the ground bar of the data center.

A.

True

B.

False