Summer Sale Special 65% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: ex2p65

Exact2Pass Menu

Question # 4

An engineer can use the ______ tool to install software for Huawei storage systems. This tool can collect and evaluate storage compatibility information in one-stop mode and supports batch installation of the UltraPath software, improving the software installation efficiency.

Full Access
Question # 5

If Huawei scale-out storage software is installed in low level design (LLD) mode, engineers need to use the ________ installation and deployment tool to plan nodes, networks, and clusters and export the configuration file for subsequent installation and deployment.

Full Access
Question # 6

Assume a financial customer purchases a Huawei OceanStor Pacific scale-out storage system for future service deployment. Which statement is false about software installation of the storage system?

A.

During block service installation, if management nodes are deployed where compute and storage nodes are converged, the number of vCPUs on each converged compute and storage node must be greater than or equal to 20.

B.

During block service installation, if converged deployment of storage and compute nodes is required, the difference between the disk quantities on any two nodes in the same storage pool cannot be greater than 2 or 30% of the disk quantity on the node having most disks.

C.

If wizard-based software installation is used, an engineer must manually add nodes, configure networks, and create a control cluster on DeviceManager, and then install the OceanStor Pacific series software.

D.

To install the Distributed Parallel Client (DPC), the memory required for running the DPC software on a compute node must be greater than or equal to 20 GB.

Full Access
Question # 7

An engineer can use multiple common management software to configure, manage, and maintain Huawei converged storage. Which of the following statements is false about the software and corresponding functions?

A.

SmartKit provides capabilities such as alarm reporting, file upload, and remote access.

B.

DeviceManager allows the engineer to allocate storage resources, manage users, manage data protection features, monitor device performance, and manage alarms.

C.

DME IQ enables cloud-based management, remote maintenance, automatic service request creation, and prediction and prevention, comprehensively improving customers’ O&M capabilities.

D.

The command-line interface (CLI) allows the engineer to allocate storage resources, manage users, manage data protection features, monitor device performance, and manage alarms.

Full Access
Question # 8

An industry customer has purchased several Huawei flash storage devices for service deployment. An engineer wants to configure the HyperSnap feature on the storage devices. However, during the configuration, the engineer discovers that snapshots cannot be created for an existing protection group. The possible cause is that the storage pool where the source LUNs in the protection group reside has no available capacity.

A.

TRUE

B.

FALSE

Full Access
Question # 9

Huawei OceanStor Pacific series is an intelligent scale-out storage product that supports large-scale scale-out and delivers high reliability. Which of the following statements are false about the product’s reliability?

A.

In terms of data reliability, multiple RAID policies are supported based on the traditional disk-level RAID mode.

B.

The product adopts Kunpeng processors to integrate functions of multiple chips and effectively improve hardware reliability.

C.

The product leverages link aggregation to ensure transmission link redundancy and performs link switchover or isolation to ensure service continuity if a link becomes faulty or subhealthy.

D.

The product uses the multi-copy technology to implement the intra-node RAID function. If a node is faulty, the system reliability is not degraded and even remains higher than that of the EC mechanism.

Full Access
Question # 10

During routine inspection, an engineer of a bank finds that an interface module of a Huawei flash storage device is faulty. In this case, the engineer can directly remove and insert the interface module without any pre-operations.

A.

TRUE

B.

FALSE

Full Access
Question # 11

In Huawei container storage solution, CSI is short for Container Storage Interface. Which of the following statements is false about Huawei CSI?

A.

CSI Driver developed by Huawei is mainly used to implement the call initiated by sidecar on Huawei storage.

B.

Huawei storage and Huawei CSI driver need to communicate with each other through RESTful to provide NAS/SAN storage resources.

C.

CSI Controller runs independently on a worker node on the Pod in StatefulSet mode and is used to interact with the storage and create and delete resources on the storage side.

D.

CSI Node runs on each worker node of Kubernetes on the Pod in DaemonSet mode and can be used to mount and unmount related storage resources.

Full Access
Question # 12

Which of the following statements are false about direct TCP offload engine (DTOE) 1.0?

A.

This technology requires CPU to process each MAC frame, which will consume a large number of CPU resources.

B.

This technology allows to directly operate the hardware queue in the user mode, avoiding the context switching overhead.

C.

This technology uses the polling mode, reducing the latency.

D.

High latency overhead still exists using the technology, such as kernel mode interrupts, locks, system calls, and thread switching.

Full Access
Question # 13

When delivering Huawei all-flash projects, Huawei engineers introduced the HyperCDP feature of flash storage to customers. Which of the following statements are true about this feature?

A.

Copies created using HyperCDP can be used for data analysis and application testing.

B.

When an application server sends a request to write data to the source LUN after a HyperCDP snapshot is created, the storage system uses the copy-on-write (COW) technology to save the new data to a new location in the storage pool and directs the source LUN’s pointer to the new location.

C.

HyperCDP snapshots cannot be directly mapped to hosts. To read data from a HyperCDP snapshot due to actual service requirements, the administrator needs to share the file system with the host so that the host can read the source file system data at the point in time when the HyperCDP snapshot was created.

D.

HyperCDP is a high-density snapshot and requires the system to construct file system objects. Therefore, the system memory usage is high.

Full Access
Question # 14

Routine management on Huawei flash storage systems involves power-on and power-off. Which of the following statements is false about power-on and power-off?

A.

Before powering on the storage system, you need to ensure that all expansion cables are correctly connected. The storage system may work improperly if the connection mode of expansion cables is adjusted after the storage system is powered on.

B.

If none of the controller enclosures in the cluster are powered on, you can log in to the BMC system using the external management IP address of the BMC and run the power-on command to power on all the controller enclosures.

C.

To power on the storage system after an emergency power-off, you need to press the power button on the controller enclosure.

D.

For Huawei OceanStor Dorado 8000 storage, after a controller enclosure is powered on, its cascaded disk enclosures will be automatically powered on.

Full Access
Question # 15

When delivering a flash storage project, Huawei engineers introduced the multi-tenant feature of flash storage to the customer. This feature isolates service data. Although different tenants cannot access each other’s LUNs, they can access each other’s file system.

A.

TRUE

B.

FALSE

Full Access
Question # 16

To prevent misoperations from affecting services, a storage system controls user operation permissions and scopes based on user levels and roles. Which of the following is not a tenant management user role in the storage system?

A.

Tenant administrator

B.

Tenant protocol administrator

C.

Tenant data protection administrator

D.

Security administrator

Full Access
Question # 17

Huawei OceanStor Pacific series storage systems support the _______ client access mode. This mode allows a single client to connect to multiple storage nodes and supports MPI-I/O access. (Enter an acronym.)

Full Access
Question # 18

A bank customer purchases several Huawei flash storage devices to store upper-layer Oracle database service data. If an Oracle database fault occurs, engineers need to collect Oracle alert log files to locate the fault. Which of the following commands cannot be used to query the alert log path?

A.

ioscan -funC disk > /home/pvlinks_disk

B.

CRS_HOME/bin/diagcollection.sh

C.

show parameter background_dump_dest

D.

db2support outpath -d db_name -c

Full Access