You'll find that our H19-311 exam questions frequently feature detailed scenarios and practical problem-solving exercises that directly mirror industry challenges. Engaging with these H19-311 sample sets allows you to effectively manage your time and pace yourself, giving you the ability to finish any Huawei Certified Pre-sales Associate- Data Center Facility practice test comfortably within the allotted time.

Question # 21

If the total current of a battery string is 1000 A and three battery strings are configured, the most economic cable configuration between the UPS and the main switch box is ():

A.

120 mm2 (382 A) x 3

B.

150 mm2 (441 A) x 3

C.

185 mm2 (506 A) x 3

D.

240 mm2 (599 A) x 3

Question # 22

The output THDv of the UPS5000-E (50 kVA power module) is (). (Multiple Choice)

A.

Linear full load < 1%

B.

Non-linear full load < 3%

C.

Linear full load < 1.5%

D.

Non-linear full load < 4%

Question # 23

The highest temperature in the local area is () when selects T3 air conditioning?

A.

30-35°C

B.

35-43°C

C.

43-55°C

D.

55-65°C

Question # 24

The typical aisle type for the FusionModule800 is ().

A.

Hot aisle

B.

Cold aisle

Question # 25

How many batteries does the UPS2000-G series (15 kVA to 20 kVA) support? () (Multiple Choice)

A.

28

B.

32

C.

36

D.

40

Question # 26

Batteries of different discharge currents have different requirements for the cutoff voltage. Typically, the () the discharge current is, the () the cutoff voltage is.

A.

Higher, higher

B.

Lower, higher

C.

Lower, lower

Question # 27

The UPS5000-A has a built-in isolation transformer.

A.

TRUE

B.

FALSE

Question # 28

The standard components and features in the typical configuration solution of the FusionModule800 include ().

A.

Temperature and humidity sensor, door status sensor, Huawei tablet, water sensor, video surveillance, and mobile app

B.

Smoke sensor, door status sensor, Huawei tablet, water sensor, simple cable trough, and video surveillance

C.

Smoke sensor, temperature and humidity sensor, Huawei tablet, alarm notification over short messages, mobile app, and easy cable trough

Question # 29

The bypass module of the UPS5000-E-200K (50 kVA power module) is the same as that of the UPS5000-E-300K.

A.

TRUE

B.

FALSE

Question # 30

Which of the following basic project information doesn't need to be entered manually before configuration quotation? ()

A.

Quotation No.

B.

Quotation name

C.

Representative office

D.

Customer name