You'll find that our H20-923_V1.0 exam questions frequently feature detailed scenarios and practical problem-solving exercises that directly mirror industry challenges. Engaging with these H20-923_V1.0 sample sets allows you to effectively manage your time and pace yourself, giving you the ability to finish any HCSP-Field-Data Center Facility V1.0 practice test comfortably within the allotted time.

Question # 4

Which of the following is the cabling mode of external power cables in IT scenarios of the FusionDC1000A?

A.

Bottom cabling

B.

End wall cabling

C.

Top cabling

D.

End door cabling

Question # 5

Which O&M practice is most effective for identifying cooling inefficiency caused by airflow problems in an operating data center?

A.

Disable temperature sensors to prevent false alarms

B.

Compare rack inlet temperatures, return air temperatures, and fan speed trends to detect recirculation and bypass

C.

Lower supply air temperature to the minimum possible value at all times

D.

Run humidification continuously regardless of ambient conditions

Question # 6

Which of the following are main components of Huawei indirect evaporative cooling system?

A.

Compressor

B.

Air filter

C.

Water pump

D.

Spray system

E.

Heat exchanger

F.

Fan

Question # 7

Which of the following control modes can be used for temperature and humidity control of smart cooling products?

A.

Cold aisle

B.

Supply air

C.

Return air

D.

Hot aisle

Question # 8

After installing the FusionCol8000-C (110–440 kW), inject water to preserve the pressure for the chilled water pipes to how many MPa. After 30 minutes, check that no leakage occurs. Preserve the pressure for 24 hours. If the pressure drop is less than 0.01 MPa and no leakage occurs, the pipes do not leak.

A.

0.8

B.

0.5

C.

1

D.

1.2

Question # 9

The default address of the WAN1 port on the ECC800-Pro is

A.

192.168.0.10

B.

192.168.248.10

C.

192.168.248.1

D.

192.168.8.10

Question # 10

Operators can view parameters and set parameters on the "User Settings" and "Comm Settings" menus.

A.

True

B.

False