Ticking Clock Black Friday Special: 75% Off! Apply coupon code below to save on all exam bundles! - Ends in 0d 00h 00m 00s - Coupon code: 75epass

Exact2Pass Menu

HPE Network Campus Access Professional Architect Exam

Last Update 1 hour ago Total Questions : 94

The HPE Network Campus Access Professional Architect Exam content is now fully updated, with all current exam questions added 1 hour ago. Deciding to include HPE7-A11 practice exam questions in your study plan goes far beyond basic test preparation.

You'll find that our HPE7-A11 exam questions frequently feature detailed scenarios and practical problem-solving exercises that directly mirror industry challenges. Engaging with these HPE7-A11 sample sets allows you to effectively manage your time and pace yourself, giving you the ability to finish any HPE Network Campus Access Professional Architect Exam practice test comfortably within the allotted time.

Question # 21

A global cruise-line company needs to modernize its existing fleet. To make the ships more cost-effective and sustainable, it will refresh the ship “insides” and replace all WLAN/LAN hardware. This refresh will not change the company’s current security requirements. The CIO also wants to minimize unused switch ports. Any future expansion will always require a hardware refresh. The effort begins with the smallest ship, which supports a maximum of 800 guests.

Each ship has a LAN infrastructure comprising two core switches, up to 10 redundant distribution switches, and up to 500 access switches (400 cabins and 100 technical rooms). The core switches are in the ship’s MDF, and the distribution switches are in the IDFs. Every cabin and technical room receives one access switch.

The ship’s cabling structure will remain unchanged. Each IDF connects to the MDF through SMF, with two pairs available for the core-to-distribution interconnect. The SM fiber between the MDF and IDF is under 300 meters (980 ft) and is OS1. Each cabin connects to the IDF through one OM2 pair, at a maximum length of 60 meters (200 ft). Each technical room connects to the IDF through one OM2 pair, with lengths from 100 to 150 meters (320 to 500 ft).

For every cabin and technical room, the customer wants to replace the existing fan-less 2530/2540 switches without altering requirements, except that the uplink to the distribution switch must be upgraded to 10GbE to accommodate increased network traffic, and technical rooms require redundant power.

The WLAN infrastructure will be refreshed 1:1, with no new cabling or AP locations. It is based on 200/300-series indoor and outdoor APs running InstantOS (fewer than 300 APs), and the customer has no WLAN requirement changes.

The cruise-line company will replace its current Internet connection before the LAN/WLAN refresh. The new connection will deliver 99.8% uptime, needed to keep paid guest Wi-Fi continuously operational. Because this Internet connection is guaranteed, the CIO wants the design based on Aruba’s ESP architecture.

Based on best practices, which switch model is the most cost-effective choice for the distribution layer?

A.

6300F 24-port SFP+ and 4-port SFP56

B.

6300M 24-port HPE Smart Rate 1/2.5/5GbE Class 6 PoE and 4-port SFP56

C.

6300M 48SR5 12p Class8 PoE and 36p Class6 PoE HPE Smart Rate 1G/2.5G/5G and 2p 50G and 2p 10G LRM

D.

6300M 24p SFP+ LRM support and 2p 50G and 2p 25G MACsec

Question # 22

Which uplink oversubscription ratios satisfy A.B.C.'s requirements, assuming they can be adjusted later based on actual performance and capacity requirements?

Choose two.

A.

12:1

B.

4:1

C.

7:1

D.

24:1

E.

1:10

Question # 23

A global cruise-line company needs to modernize its existing fleet. It will refresh the ship’s “insides” to reduce costs and improve sustainability, replacing all WLAN/LAN hardware. During this refresh, the company will retain its existing security requirements. The CIO also wants to minimize the number of unused switch ports. Any future expansion will always require a hardware refresh. The project starts with the smallest ship, which supports a maximum of 800 guests.

Each ship has a LAN infrastructure with two core switches, up to 10 redundant distribution switches, and up to 500 access switches (400 cabins and 100 technical rooms). The core switches reside in the ship’s MDF, while distribution switches reside in the IDFs. Each cabin and technical room receives one individual access switch.

The ship’s cabling infrastructure will not be refreshed. Every IDF connects to the MDF using SMF, with two pairs available for the core-to-distribution interconnect. The SM fiber between the MDF and IDF is under 300 meters (980 ft) and is OS1. Each cabin connects to its IDF using one OM2 pair, at a maximum distance of 60 meters (200 ft). Each technical room connects to its IDF with one OM2 pair, at distances from 100 to 150 meters (320 to 500 ft).

For every cabin/technical room, the customer wants to replace the current fanless 2530/2540 switches without altering requirements, except that the uplink to the distribution switch must be upgraded to 10GbE to accommodate increased network traffic, and technical rooms require redundant power.

The WLAN infrastructure will be refreshed 1:1, with no new cabling or AP locations. The WLAN uses 200/300 Series indoor and outdoor APs running InstantOS (fewer than 300 APs), and the customer has no changes to WLAN requirements.

The cruise-line company will replace its existing Internet connection before the LAN/WLAN refresh. The new Internet connection will offer 99.8% uptime, required to keep paid guest Wi-Fi continually operational. With this new Internet connection, the CIO wants to base the design on Aruba’s ESP architecture because the Internet connection is guaranteed.

Based on best practices and customer requirements, which switch series should be recommended for the core?

A.

8320 Series

B.

8360 Series

C.

8325 Series

D.

8400 Series

Question # 24

You meet with a customer to update the network after the prior network manager has left the company for another role.

Which methods can validate the current network state when the available network documentation is invalid?

Choose two.

A.

Begin searching through file shares for old documentation and compare the files and drawings to each other.

B.

Use neighbor discovery protocols to learn neighbor relationships, document the connections, and build a topology from the learned information.

C.

Physically examine the network devices to hand-over-hand validate the connections from device-to-device documenting the connections and cabling type if possible.

D.

Interview random company staff to gather the 'tribal knowledge' of how the network functions during normal operations and during degraded states.

E.

Documenting existing network configuration and topology is not required because previous iterations of network designs are considered obsolete.

Question # 25

Manufacturing A.B.C. is an international, mid-sized company that specializes in manufacturing industrial equipment. It has operated in the market for more than two decades and has become a reputable player in its industry. However, rapid technological advances have left its present network infrastructure outdated and unable to keep pace with modern manufacturing-process demands.

Manufacturing A.B.C.'s network combines multi-vendor legacy wired and wireless components, resulting in frequent downtime and reduced production efficiency. Its aging equipment causes slow data-transfer rates, unreliable connectivity, and greater exposure to cyber threats. Fiber cabling should also be upgraded because OM2 is used for the most part.

Further compounding the network problems, the recent departure of the CTO has left the company without a clear course for the network-refresh project. The management team lacks consensus on the upgrade's scope, budget, and timeline.

The manufacturing customer's primary objectives are:

    Improve network performance and reliability to improve production processes and minimize downtime.

    Strengthen network security to safeguard sensitive data and intellectual property.

    Streamline communication and collaboration among the organization's different departments.

    Provide scalability for future growth and technological advances.

Manufacturing A.B.C. wants a comprehensive network refresh that includes:

    Upgrading the wired infrastructure with high-speed Ethernet switches to support higher data-transfer rates and lower latency.

    Deploying a robust wireless solution using enterprise-grade access points to provide seamless connectivity throughout the manufacturing facility.

    Centralized network-management tools to simplify network administration and monitoring.

Expectations:

The customer expects the network-refresh project to be completed efficiently, with minimal disruption to ongoing operations. They want a reliable, experienced network-solutions provider that understands their distinctive manufacturing requirements and can deliver a tailored solution that meets their budget constraints. Given the recent CTO change, the manufacturing customer is eager to receive clear project proposals and decision-making support.

As the network-solutions provider, your role is to address these concerns, provide expert guidance, and present a clearly defined plan that effectively meets their objectives.

Assume that the current network infrastructure has no wireless shadow-IT equipment operating across the different floors/production sites, but you want to confirm this. How can you determine whether wireless shadow-IT equipment is currently in operation?

A.

Do a ping sweep and document the hostnames/responses. Find out the connected switch port and walk to this location.

B.

Ask employees if they use 3rd party equipment to create isolated Hotspots.

C.

Do a passive site survey, analyze the outcome together with the customer, and decommission this equipment wherever possible.

D.

Use a wireless sniffer like Wireshark to scan the environment and look for anomalies.

Question # 26

XYZ Regional Hospital is an integrated healthcare system consisting of hospitals, neighborhood health centers, and small doctor offices. XYZ Regional Hospital recently merged with 4x neighborhood health centers and 125 doctor branch offices. Its wireless, wired-access, and AAA solutions are outdated and require replacement.

XYZ Regional Hospital wants to future-proof and improve efficiency at all sites by enhancing wired and wireless access and moving to centralized, unified wired/wireless and policy management that provides uninterrupted availability for all systems.

Locations:

    XYZ Regional Hospital is in New York City.

    Dila Health Center is in City A.

    Mount Health Center is in City B.

    Rock Health Center is in City C.

    Branch clinics are in different locations across the United States.

Requirements:

    Provide, through management software, a single pane of glass to manage wired and wireless LANs and VPNs across campus, branch, and remote environments through a web/cloud architecture that delivers near-real-time insight, troubleshooting tools, and Service Level performance reporting.

    Provide seamless integration across wired, wireless, WAN, SD-Branch, and IoT.

    Provide secure wireless access for all Regional Hospital employees and partners, and provide wireless Internet access to medical citizens when they visit the facilities.

    All access points must support these features and specifications: 802.11 ax (Wi-Fi 6E Certified).

    Include security options such as WP2/WPA3 and 802.1X with Radius secure authentication.

    Identify and authenticate every wireless and wired device.

    Provide end-to-end role-based security.

    Provide seamless mobility across the hospital for medical teams, patients, and visitors.

    Reduce Wi-Fi deployment time from days to hours and enable Zero-Touch deployments across the site.

    Establish a resilient, future-ready network infrastructure with the intelligence, scalability, and intuitive toolsets needed to meet emerging needs.

    Provide a fully redundant branch solution with dynamic path selection to the hospital.

The hospital CIO wants to review the phase 1 approach and framework that will be used to achieve the network-refresh project goals.

What is the phase 1 task?

A.

The team will define and document a path for the current to future support model, including any staffing, skills, and professional development that is recommended.

B.

Kickoff the project to identify the team members involved, review the deliverables, expectations, timeframes, and begin the discovery/data collection.

C.

Meet with ITS Network/Telecom and support staff following the knowledge transfer sessions to educate the ITS team on campus, data center, and network security options.

D.

Review the potential design options and further scope deployment efforts, phased implementation approaches, enablement options, and operational expertise requirements.

Question # 27

A large multinational financial institution has hired you to design a new full-stack wired and wireless network for its new 6-story regional office building. The lowest two floors of the facility will be retail space for a large banking branch. The upper floors will be carpeted corporate office space, with each floor measuring approximately 100,000 sq ft (9290 sq m). All data centers are offsite and are outside this project’s scope. The customer is underserved by its current L2-based network infrastructure and wants to apply modern best practices in the new design. The network must be fully resilient and fault-tolerant, with dynamic segmentation at the edge.

The retail space will provide public guest Wi-Fi access. Retail associates will use corporate tablets for customer service, and the retail floors will contain a mix of wired and wireless devices. Corporate users will primarily connect wirelessly, although several wired clients, printers, and hard VoIP phones will also be used.

The customer also plans to renovate the corporate office space to take advantage of 'smart office' technology. These enhancements will enable blue-dot wayfinding, presence analytics, and other location-based services.

The client wants to use lower-cost OS-CX switches in its wiring closets. It calculates that each closet will require a stack of qty 6 POE (AT) and qty 4 Gigabit Ethernet switches, stacked with low-cost DACs.

Which switch series should you recommend?

A.

CX 6100

B.

CX 6000

C.

CX 6300F

D.

CX 6200M

Question # 28

Which type of member must be rebooted when performing an In-Service Software Upgrade within a VSF stack?

A.

Conductor

B.

Member

C.

all member types

D.

Standby

Go to page: