You'll find that our NCSC-Level-1 exam questions frequently feature detailed scenarios and practical problem-solving exercises that directly mirror industry challenges. Engaging with these NCSC-Level-1 sample sets allows you to effectively manage your time and pace yourself, giving you the ability to finish any Nutanix Certified Services Consultant (NCSC): Level 1 practice test comfortably within the allotted time.
A customer wants to use NIC teaming on an ESXi host using a vSphere Standard Switch configured with the Route based on physical NIC load load balancing option. The customer does not see the option when editing the Teaming and Failover settings for the switch.
How should the consultant resolve this issue?
What is the minimum number of nodes required for a Nutanix Cluster to support Replication Factor 3 (RF3) on a storage container?
To prepare for a new Nutanix installation, a consultant downloads the Foundation VM, imports the VM to their Desktop Virtualization Solution, and powers on the VM. The IPv4 static address on the host workstation and the Foundation VM have been configured, but pings between them fail.
Which two troubleshooting steps should the consultant perform? (Choose two.)
Refer to the exhibit.
A consultant is installing AOS 5.10 and ESXi 6.5 on three nodes. During the Foundation process, ESXi 6.5 is not available as one of the choices for hypervisor.
Which solution should the consultant use?
A consultant finishes creating a new ESXi cluster. The consultant connects to the nodes via laptop and a personal flat switch. The host/CVM network is on VLAN 23. The customer has the native VLAN on the ToR switches set to 23.
The customer wants to use LACP. Before placing the nodes on the customer network, the consultant tags VLAN 23 for each host and CVM. The consultant connects the nodes to the customer network and finds that they are unreachable.
What is causing this issue?
A customer has a G6 AHV cluster with 4x10GbE NICs on each node and the following configuration:
* Networking is set to default
* Only two NICs are connected
The customer receives the following critical message:
The NIC is disconnected from the switch, or the switchport is failing.
What should the consultant verify to resolve the issue?
A consultant is unable to install virtualization software on a laptop.
Which two versions of Foundation can be used to resolve this issue? (Choose two.)