Spring Sale Special Limited Time 70% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: buysanta

Exact2Pass Menu

Nutanix Certified Services Consultant (NCSC): Level 1

Last Update 11 hours ago Total Questions : 78

The Nutanix Certified Services Consultant (NCSC): Level 1 content is now fully updated, with all current exam questions added 11 hours ago. Deciding to include NCSC-Level-1 practice exam questions in your study plan goes far beyond basic test preparation.

You'll find that our NCSC-Level-1 exam questions frequently feature detailed scenarios and practical problem-solving exercises that directly mirror industry challenges. Engaging with these NCSC-Level-1 sample sets allows you to effectively manage your time and pace yourself, giving you the ability to finish any Nutanix Certified Services Consultant (NCSC): Level 1 practice test comfortably within the allotted time.

Question # 21

For a new AHV cluster installation, a customer has 20 NX-8155-G6 nodes with quad port SFP NICs.

The customer wants to meet the following guidelines:

* Take advantage of all available 10GbE links

* Achieve maximum throughput per VM

* Use of redundant ToR switches

* Fastest reconvergence during link failure

How should the load balancing be configured on the host?

A.

ovs-vsctl set port br0-up bond_mode=balance-slb

ovs-vsctl set port br0-up other_config:bond-rebalance-interval=30000

ovs-vsctl set port br0 tag=10

B.

ovs-vsctl set port br0-up bond_mode=active-backup

ovs-vsctl set port br0-up other_config:bond-rebalance-interval=30000

C.

ovs-vsctl set port br0-up bond_mode=balance-slb

D.

ovs-vsctl set port br0-up other_config:lacp-fallback-ab=true

ovs-vsctl set port br0-up lacp=active

ovs-vsctl set port br0-up bond_mode=balance-tcp

Question # 22

A consultant is preparing to foundation over a customer network that has the following criteria:

* VLAN segmented network

* VLAN tags on the nodes must be imaged prior to starting the foundation process.

For each node, the consultant has done the following:

* Connected to the Network Crash Cart of the Node

* Logged in using “root” credentials

What should the consultant do next?

A.

1. CD to /root/nutanix-network-crashcart/

2. Start Network Utility tool by running: ./network_configuration

3. Change Values

B.

1. CD to /home/data/nutanix/nutanix-network-crashcart/

2. Start Network Utility tool by running: ./network_configuration

3. Change Values

C.

1. Log into CVM using nutanix@192.168.5.254

2. CD to /root/Nutanix-network-crashcart/

3. Start Network Utility tool by running: ./network_configuration

4. Change Values

D.

1. Log into CVM using nutanix@192.168.5.254

2. CD to /home/data/nutanix/nutanix-network-crashcart/

3. Start Network Utility tool by running: ./network_configuration

4. Change Values

Question # 23

A customer has an ESXi Cluster with two 10GbE NICs on each node with the following requirements:

* Solution must follow Nutanix Best Practices

* Network configuration should be redundant

* A vSphere Standard Switch must be utilized

Which load balancing method should be used?

A.

Route based on originating port ID

B.

Route based on physical NIC load

C.

Route based on IP hash

D.

Route based on source MAC hash

Go to page: