Ticking Clock Black Friday Special: 80% Off! Apply coupon code below to save on all exam bundles! - Ends in 0d 00h 00m 00s - Coupon code: 80OFFBF

Exact2Pass Menu

Tech in Surgery - Certified (NCCT), TS-C (NCCT)

Last Update 1 hour ago Total Questions : 175

The Tech in Surgery - Certified (NCCT), TS-C (NCCT) content is now fully updated, with all current exam questions added 1 hour ago. Deciding to include TS-C practice exam questions in your study plan goes far beyond basic test preparation.

You'll find that our TS-C exam questions frequently feature detailed scenarios and practical problem-solving exercises that directly mirror industry challenges. Engaging with these TS-C sample sets allows you to effectively manage your time and pace yourself, giving you the ability to finish any Tech in Surgery - Certified (NCCT), TS-C (NCCT) practice test comfortably within the allotted time.

Question # 31

The surgical technologist and circulating nurse have completed the initial instrument and sterile supply count at the beginning of a case. All counts are correct, and all sponges are accounted for on the sterile field. The surgical technologist notices that the trash containers are full. Which action should the surgical technologist ask the circulating nurse to perform?

A.

Change the container and leave the trash in the room.

B.

Change the container and place the trash in the substerile area.

C.

Change the container, label the trash, and place it in the substerile area.

D.

Change the container, remove the trash from the room, and place it in the designated area before the initial incision.

Question # 32

The surgeon has completed the reanastomosis of the femoral artery using a 6-0 Prolene suture. The surgeon is preparing to tie the knot. Which of the following should the surgical technologist anticipate NEXT?

A.

Gelfoam and thrombin

B.

Another stitch

C.

Suture scissors to cut the stitch

D.

Wet the surgeon ' s hands with saline

Question # 33

When disposing of sharps after surgery, in which of the following locations should the sharps be placed FIRST?

A.

Kidney basin

B.

Metal basin

C.

Sharps book

D.

Sent to central processing on the back table

Question # 34

When positioning a patient in adjustable gel-padded lithotomy stirrups, which nerve should be protected?

A.

Peroneal nerve

B.

Obturator nerve

C.

Sciatic nerve

D.

Ulnar nerve

Question # 35

Which of the following should the surgical technologist have available in the event of a laser fire during surgery?

A.

Balanced salt solution (BSS)

B.

Normal saline

C.

Sterile water

D.

Lactated Ringer ' s solution

Question # 36

Which anatomical structure can be easily accessed when the surgeon makes an incision in the right upper quadrant of the abdomen?

A.

Liver

B.

Appendix

C.

Sigmoid colon

D.

Spleen

Question # 37

A pregnant patient presents to the emergency department with right upper quadrant abdominal pain and is scheduled for surgery. She is currently in the third trimester of pregnancy. Which of the following procedures should the surgical technologist anticipate?

A.

Splenectomy

B.

Gastrectomy

C.

Bowel resection

D.

Appendectomy

Question # 38

Place the following structures in the correct order of tissue closure for a cesarean section performed through a Pfannenstiel incision, proceeding from the innermost layer to the outermost layer of the abdominal cavity.

Available options: Uterus, Skin, Subcutaneous Tissue (Sub-Q), Peritoneum, Fascia.

Question # 39

Which of the following surgical products is contraindicated when a patient has a shellfish allergy?

A.

Methylene blue

B.

Iodine

C.

Surgicel

D.

Hibiclens

Question # 40

A surgical technologist is preparing for a laparoscopic-assisted vaginal hysterectomy (LAVH). While gathering the operating room equipment, the circulating nurse obtains stirrups for patient positioning and asks why two instrument tables are required. How should the surgical technologist respond?

A.

One table is used to open all equipment, and the other is used during the procedure.

B.

One table is used for specimens, and the other is used for contaminated instruments.

C.

One table is for the sterile procedure, and the other is for the clean-contaminated procedure.

D.

One table is used to transport contaminated instruments to the Sterile Processing Department.

Go to page: