You'll find that our 150-820 exam questions frequently feature detailed scenarios and practical problem-solving exercises that directly mirror industry challenges. Engaging with these 150-820 sample sets allows you to effectively manage your time and pace yourself, giving you the ability to finish any Brocade Certified Ethernet Fabric Professional 2015 practice test comfortably within the allotted time.
Referring to the exhibit, you connected your Brocade VDX device to an Ethernet switch running PVST+. The interfaces are up but spanning tree is not functioning for VLAN 10.
VDX8770_3-131#sh run prot
protocol spanning-tree rpvst
!
VDX8770_3-131# sh run int vlan 10
interface Vlan 10
!
VDX8770_3-131#sh run int te 131/2/16
interface TenGigabitEthernet 131/2/16
fabric isl enable
fabric trunk enable
switchport
switchport mode trunk
switchport trunk allowed vlan add 10
switchport trunk tag native-vlan
no spanning-tree shutdown
no shutdown
What is the problem?
Referring to the exhibit, you are experiencing latency issues on interface Te 27/0/60.
switch# show interface tengigabitethernet 27/0/60
TenGigabitEthernet 27/0/60 is up, line protocol is up (connected)
Hardware is Ethernet, address is 0005.3367.26d8
Current address is 0005.3367.26d8
Pluggable media present
Interface index (ifindex) is 283874428169
MTU 2500 bytes
LineSpeed Actual : 10000 Mbit
LineSpeed Configured : Auto, Duplex: Full
Flowcontrol rx: off, tx: off
Last clearing of show interface counters: 22:07:59
Queueing strategy: fifo
Receive Statistics:
15254 packets, 1395269 bytes
Unicasts: 10641, Multicasts: 2637, Broadcasts: 1976
64-byte pkts: 10874, Over 64-byte pkts: 3294, Over 127-byte pkts: 117
Over 255-byte pkts: 969, Over 511-byte pkts: 0, Over 1023-byte pkts: 0
Over 1518-byte pkts(Jumbo): 0
Runts: 0, Jabbers: 0, CRC: 1128350, Overruns: 0
Errors: 1128350, Discards: 0
Transmit Statistics:
12633 packets, 1155963 bytes
Unicasts: 18, Multicasts: 12615, Broadcasts: 0
Underruns: 0
Errors: 0, Discards: 0
Rate info (interval 299 seconds):
Input 0.000128 Mbits/sec, 0 packets/sec, 0.00% of line-rate
Output 0.000000 Mbits/sec, 0 packets/sec, 0.00% of line-rate
Time since last interface status change: 0d00h40m
What are two reasons for the problem? (Choose two.)
Router 2 has failed. You want to know what will happen when Host 3 tries to send traffic to the Internet.

Referring to the exhibit, which statement is correct?
Which vendor's Ethernet fabric solution will directly join a Brocade VCS Fabric?
You are using VxLANs to extend your L2 domains over your L3 networks.
What is added to the VxLAN to do this?
Your customer is replacing a Brocade VDX 6740 (RBridge ID 2) to an existing VCS fabric in logical chassis mode with VCSID 2. They would like to migrate the port configurations to the new switch when the uplinks are connected.
Which two actions are necessary for the replacement? (Choose two.)
You have implemented flow-based sFlow in your Brocade VCS Fabric by enabling sFlow globally on each Brocade VDX. You are not receiving any statistics in your sFlow collector from these devices.
What must happen to start collecting data?
Referring to the exhibit, which statement is correct?
Exhibit:
VDX8770_3-131# sh port-c 123
LACP Aggregator: Po 123
Aggregator type: Standard
Ignore-split is enabled
Admin Key: 0123 - Oper Key 0123
Partner System ID - 0x0000,00-00-00-00-00-00
Partner Oper Key 0000
Member ports on rbridge-id 131:
Link: Te 131/2/16 (0x8318880086) sync: 0
VDX8770_3-131# show running-config interface Port-channel 123
interface Port-channel 123
vlag ignore-split
switchport
switchport mode trunk
switchport trunk allowed vlan add 10,30
switchport trunk tag native-vlan
spanning-tree shutdown
no shutdown
Exhibit:
You are troubleshooting an FCoE login problem in your environment. The port shown in the exhibit has not been able to log into the fabric. The default FCoE fabric map in your environment has not been changed.
Interface TenGigabitEthernet 3/0/4
Mode PFC
DCBX enabled for PFC negotiation
TX 0 frames
TX TX RX RX Output Paused
CoS Admin Oper Admin Oper 512 BitTimes
---------------------------------------
0 Off Off Off Off 0
1 Off Off Off Off 0
2 Off Off Off Off 0
3 On Off On Off 0
4 Off Off Off Off 0
5 Off Off Off Off 0
6 Off Off Off Off 0
7 Off Off Off Off 0
sw0(conf-if-te-3/0/1-24)# do show lldp neighbors interface ten 3/0/4 detail
Neighbors for Interface Te 3/0/4
--- < OUTPUT TRUNCATED > ---
DCBX TLVs
===========
Version : CEE
DCBX Ctrl OperVersion: 0 MaxVersion: 0 SeqNo: 4 AckNo: 6
DCBX ETS OperVersion: 0 MaxVersion: 0 Enabled: 1 Willing: 0 Error: 1
Enhanced Transmission Selection (ETS)
Priority-Group ID Map:
Priority : 0 1 2 3 4 5 6 7
Group ID : 0 0 0 0 1 0 0 0
Group ID Bandwidth Map:
Group ID : 0 1 2 3 4 5 6 7
Percentage: 50 50 0 0 0 0 0 0
Number of Traffic Classes supported: 2
DCBX PFC OperVersion: 0 MaxVersion: 0 Enabled: 0 Willing: 0 Error: 1
Priority-based Flow Control (PFC)
Enabled Priorities: 3
Number of Traffic Class PFC supported: 8
FCoE App OperVersion: 0 MaxVersion: 0 Enabled: 1 Willing: 0 Error: 0
FCoE Application Protocol
User Priorities: 4
What are two causes of the problem? (Choose two.)
A customer implements a fault tolerant network and has requested that the switches in the data center support multiple management modules.
Which two Brocade VDX switches would you recommend for this requirement? (Choose two.)