You'll find that our API-SIEE exam questions frequently feature detailed scenarios and practical problem-solving exercises that directly mirror industry challenges. Engaging with these API-SIEE sample sets allows you to effectively manage your time and pace yourself, giving you the ability to finish any Source Inspector Electrical Equipment practice test comfortably within the allotted time.

Question # 4

Machine vibration measurement using non contacting probes are taken:

A.

on horizontal, vertical and the axial directions on the baseplate.

B.

on the shaft at 1.2 times the running speed.

C.

on the frame during residual unbalance with the feet unclamped.

D.

on horizontal, vertical and the axial directions on the bearing housings.

Question # 5

What is the purpose of an insulation resistance reading?

A.

To evaluate the insulation and condition of the grounding

B.

To determine the resistance of the conductors

C.

To evaluate the condition of the insulation between conductors and ground

D.

To determine if the conductors are properly terminated

Question # 6

Apparent power is measured in:

A.

mhos.

B.

vars.

C.

volt-amperes.

D.

watts.

Question # 7

According to NFPA 70, is the use of Teflon tape on threaded connections for conduits allowed?

A.

Only when installed in a Class I, Division 2 area

B.

Yes, the use of Teflon on metal raceways, cable armor, and other metal enclosures prevents water from entering

C.

No, metal raceways and other metal enclosures for conductors shall be metallically joined together into a continuous electrical conductor

D.

Yes, the use of Teflon ensures an explosion proof vapor seal

Question # 8

What would the equipment pictured below be used for?

A.

Precise measurement of shaft alignment

B.

Precise measurement of machined equipment requiring close tolerances

C.

Calibration of precision measuring equipment

D.

Verification of proper spacing between motor and gearbox

Question # 9

What document provides information on design and installation of electrical systems for fixed and floating offshore petroleum facilities for unclassified and Class I, Zone 0, Zone 1 and Zone 2 locations?

A.

NFPA 70

B.

IEEE 841

C.

API RP 14F

D.

API RP 14FZ

Question # 10

What is the common industry term used for the dielectric withstand test?

A.

Hipot test

B.

Voltage test

C.

Current test

D.

Capacitor microfarad dielectric test