Weekend Sale Limited Time 70% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: buysanta

Exact2Pass Menu

Question # 4

Which parameters can be defined when sizing a Dell Unity XT solution using the Simple Performance method?

A.

Read size (KB) Target IOPS

B.

Write size (KB) Initial capacity (TB)

C.

Application workload type Yearly growth rate (%)

D.

Days hot Number of LUNs

Full Access
Question # 5

A customer has three Dell PowerStore 1000Ts in a cluster and wants to add a PowerStore 5000X. What must they do?

A.

Create a cluster with the 5000X.

B.

Use the PowerStore CLI to add the appliance.

C.

Reconfigure the existing cluster.

D.

Use the PowerStore Manager to add the appliance.

Full Access
Question # 6

Which two workload parameters are required to proceed with sizing for a PowerStore solution? (Select 2)

A.

Response time

B.

IOPS

C.

Effective Capacity

D.

Data reduction ratio

Full Access
Question # 7

Which two parameters avoid bottlenecks and improve performance when sizing Dell Unity XT storage solutions? (Select 2)

A.

Network Bandwidth

B.

Port Utilization

C.

Port load balancing

D.

Network Latency

E.

Workload Types

Full Access
Question # 8

What result is obtained by multiplying the VM count by the Capacity per VM in a PowerStore system?

A.

Usable Capacity

B.

Raw Capacity

C.

Effective Capacity

Full Access
Question # 9

What is a Dell recommendation when connecting ESXi hosts to PowerStore?

A.

Configure Round Robin Multipathing with an IOPS limit of 1024.

B.

Enable DelayedACK when configured using iSCSI.

C.

Configure a minimum of two NAS servers when using vVol Datastores.

D.

Use the default 8k host I/O size when using NFS.

Full Access
Question # 10

A PowerStore solution must support hosts using 100 Gb/s Eth connectivity and hosts using 16 Gb/s FC connectivity. How should the I/O Modules be populated according to Dell Best Practices?

A.

100 Gb/s Eth I/O Module in Slot 0 and 16 Gb/s FC I/O Module in Slot 1

B.

100 Gb/s Eth I/O Module in Slot 1 and 16 Gb/s FC I/O Module in Slot 0

C.

100 Gb/s Eth and 16 Gb/s FC I/O Modules can be placed into any Slot

Full Access
Question # 11

What is the minimum number of drives in a RAID 6 dynamic pool?

A.

8

B.

9

C.

6

D.

7

Full Access
Question # 12

What is the maximum supported drive configuration in the base enclosure of the PowerStore 3200T?

A.

23xNVMe SCMs 2 x NVMe NVRAM

B.

21 x NVMe SSDs 2 x NVMe NVRAM

C.

23 x NVMe SSDs 2 x NVMe NVRAM

D.

21 x NVMe SCMs 4 x NVMe NVRAM

Full Access
Question # 13

What is a Dell recommendation when connecting ESXi hosts to PowerStore?

A.

Use the default 32k host I/O size when using VMware NFS Datastores.

B.

Configure a minimum of two NAS servers when using vVol Datastores.

C.

Configure Round Robin Multipathing with an IOPS limit of 1024.

D.

Disable DelayedACK when configured using iSCSI.

Full Access
Question # 14

Which two attributes characterize I/O workloads for sizing the PowerStore storage solution? (Select 2)

A.

Extent of Serialization

B.

Splitting of Workloads

C.

Random vs. Sequential I/O

D.

Read vs. Write ratios

E.

CloudIQ Reporting

Full Access
Question # 15

What information must a solution architect gather before they start designing a storage solution?

A.

Application response, LAN, and WAN requirements

B.

Network Infrastructure, Storage, and Customer workload performance requirements

C.

LAN, SAN, and IOPS requirements

D.

LAN, SAN, and Customer workload requirements

Full Access
Question # 16

Which disk format is recommended when deploying a Dual-SP Dell Unity VSA?

A.

Thick Provision Eager Zeroed

B.

Thin Provisioned

C.

Thick Provision Lazy Zeroed

Full Access
Question # 17

A company has a Dell Unity XT 880 at its Boston site providing file storage for a business production application. The company has a second remote site 8 km (5 mi) away in Cambridge. A third site is in New York (342 km (213 mi) from the Boston site). How can the same production data be protected against system outage with a zero RPO and a maximum of 15 minutes RPO data recovery?

A.

Synchronous replicate from Boston to Cambridge Asynchronous replicate from Boston to New York

B.

Synchronous replicate from Boston to Cambridge Synchronous replicate from Boston to New York

C.

Asynchronous replicate from Boston to Cambridge Asynchronous replicate from Cambridge to New York

D.

Synchronous replicate from Boston to Cambridge Synchronous replicate from Cambridge to New York

Full Access
Question # 18

What is the maximum throughput per port in backend 12 GB SAS ports in Dell Unity XT arrays?

A.

2,000 Mbps

B.

2,500 Mbps

C.

25,000 Mbps

D.

250 Mbps

Full Access
Question # 19

What are the inputs and outputs of the Unity Designer tool?

A.

Inputs: Sales order, Sizing XML file, System configuration PDF file Outputs: Detailed design, Excel configuration guide report

B.

Inputs: Sales order, Excel configuration guide report, Detailed design Outputs: Sales order, Sizing XML file, System configuration PDF file

C.

Inputs: Sales order, Detailed design, Excel configuration guide report Outputs: Sizing XML file, System configuration PDF file

D.

Inputs: Sales order, Sizing XML file, System requirements Excel file Outputs: Detailed design, Excel configuration guide report, System configuration PDF file

Full Access
Question # 20

Which Dell Unity XT DPE front-end port connectivity can support up to 30,000 IOPS/port and up to 1,700 MB/s?

A.

25 GbE iSCSI

B.

16 Gb FC

C.

10 GbE iSCSI and 16 Gb FC

D.

16 Gb FC and 25 GbE iSCSI

Full Access
Question # 21

What initiates an automatic NAS server failover to the peer SP?

A.

Assisted internal migration

B.

Network link failure

C.

SP hardware fault

D.

Resource balancing algorithm

Full Access
Question # 22

An application owner needs 10 volumes for their application to be created, and they must have snapshots taken simultaneously with write-order-consistency. Which feature in Dell PowerStore should be used to enable this requirement?

A.

Volume Groups

B.

Snapshot Groups

C.

Data Groups

D.

Consistency Groups

Full Access
Question # 23

The CPU utilization in a Dell Unity XT system is currently at 68%. What is the level of CPU utilization?

A.

Extremely High Utilization

B.

High Utilization

C.

Low Utilization

D.

Normal Utilization

Full Access
Question # 24

What benefit do higher capacity drives provide in a Dell Unity All Flash array?

A.

Larger I/O size

B.

Less physical space is used

C.

Efficient utilization of front end ports

Full Access
Question # 25

What is done during the preconfigure step of a PowerStore block import migration?

A.

Source system is added to the PowerStore.

B.

Destination volume is created.

C.

Network connectivity is set up.

D.

Import schedule is set.

Full Access
Question # 26

What is recommended maximum cable length for PowerStore back-end NVMe cabling to avoid performance issues?

A.

100 meters

B.

10 meters

C.

3 meters

D.

5 meters

Full Access