Spring Sale Special Limited Time 70% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: buysanta

Exact2Pass Menu

LEED AP Interior Design + Construction (LEED AP ID+C) V4

Last Update 9 hours ago Total Questions : 100

The LEED AP Interior Design + Construction (LEED AP ID+C) V4 content is now fully updated, with all current exam questions added 9 hours ago. Deciding to include LEED-AP-ID+C practice exam questions in your study plan goes far beyond basic test preparation.

You'll find that our LEED-AP-ID+C exam questions frequently feature detailed scenarios and practical problem-solving exercises that directly mirror industry challenges. Engaging with these LEED-AP-ID+C sample sets allows you to effectively manage your time and pace yourself, giving you the ability to finish any LEED AP Interior Design + Construction (LEED AP ID+C) V4 practice test comfortably within the allotted time.

Question # 21

A tenant space includes an open office floor plan of 100 workstations and 10 enclosed offices where each workspace is designed for individual use. Based on the requirements of Indoor Environmental Quality Credit, Interior Lighting,

what is the minimum number of occupants requiring individual controls to achieve one point?

A.

81 occupants

B.

90 occupants

C.

99 occupants

D.

100 occupants

Question # 22

The project material costs for Building Product Disclosure and Optimization cost-based credits are

A.

actual costs, furniture included

B.

default costs, 30% of total construction cost

C.

actual costs, furniture optional

D.

default costs, 40% of total construction cost

Question # 23

A project team is pursuing certification for a performing arts center in an urban neighborhood. The project will earn one point from the Location and Transportation Credit, Surrounding Density and Diverse Uses. The project team is considering the Location and Transportation Credit for Reduced Parking Footprint. Which of the following needs to be included in the credit calculation?

A.

The project is located in an area without a code minimum and cannot meet this credit

B.

A 20% reduction in the number of parking spaces from the calculated base ratio of the performing arts center

C.

Existing on-street parking spaces in the public right-of-way along the street in front of the project's main entrance

D.

Existing parking spaces in a privately-owned parking deck being leased to the project staff that are 1/8 mi.

(0.40 km) away

Question # 24

Which of the following appliances are included in Water Efficiency Prerequisite, Indoor Water Use Reduction?

A.

Commercial dishwashers and coffee makers

B.

Residential clothes washers and dishwashers

C.

Residential dishwashers and drinking fountains

D.

Commercial clothes washers and coffee makers

Question # 25

A mechanical engineer needs to determine the number of carbon dioxide monitors needed for the public area of a hotel. The public area includes the hotel front desk, the hotel lobby, two public restrooms and one corridor.

The aim is to achieve Indoor Environmental Quality Credit, Enhanced Indoor Air Quality Strategies, Option 2. Additional Enhanced IAQ Strategies, Part C. Carbon Dioxide Monitoring. The project's LEED AP

should recommend a minimum of how many CO2 monitors?

A.

One

B.

Two

C.

Four

D.

Five

Question # 26

A tenant moves into an existing building where no modifications to the building envelope will be made. What credit would be affected by the visible light transmittance of the existing exterior glazing?

A.

Indoor Environmental Quality Credit, Daylight

B.

Indoor Environmental Quality Credit, Quality Views

C.

Materials and Resources Credit, Interiors Life-Cycle Impact Reduction

D.

Energy and Atmosphere Credit, Fundamental Commissioning and Verification

Question # 27

The contractor has submitted waste hauling reports for review in order to achieve Materials and Resources Credit, Construction and Demolition Waste Management. Which of the following by-products on the documentation contribute toward the credit?

A.

Excavated soil

B.

Wood derived fuel

C.

Items sent to the local incinerator

D.

Fine waste used as Alternate Daily Cover

Question # 28

Which of the following can be considered pre-consumer recycled content?

A.

Aluminum cans used to make sheet metal

B.

Plastic bottles that are used to create upholstery fabric

C.

Sawdust from a lumber mill used to make composite board

D.

Glass manufacturing scraps (culls) that are used to create new glass

Question # 29

The use of MERV 13 (F7) air filters is required to obtain what credit?

A.

Energy and Atmosphere Credit, Advanced Energy Metering

B.

Energy and Atmosphere Credit, Optimize Energy Performance

C.

Indoor Environmental Quality Credit, Enhanced Indoor Air Quality Strategies

D.

Indoor Environmental Quality Credit, Construction Indoor Air Quality Management Plan

Question # 30

A project is pursuing Indoor Environmental Quality Credit, Interior Lighting, Option 1. Lighting Control. Which lighting control could the design team specify to meet the credit requirements for open-office workstations?

A.

Standard on-off switches at each workstation

B.

Plug-in task light at each workstation that allow for on, off and a 50% light level

C.

Overhead lighting for the open-office space with fully automatic dimming via daylight sensors for the space

D.

Overhead lighting for the open-office space with controls that allow for on, off and a 50% light level for the space

Go to page: