Ticking Clock Black Friday Special: 75% Off! Apply coupon code below to save on all exam bundles! - Ends in 0d 00h 00m 00s - Coupon code: 75epass

Exact2Pass Menu

NetApp Hardware Support Engineer Professional Exam

Last Update 1 hour ago Total Questions : 81

The NetApp Hardware Support Engineer Professional Exam content is now fully updated, with all current exam questions added 1 hour ago. Deciding to include NS0-094 practice exam questions in your study plan goes far beyond basic test preparation.

You'll find that our NS0-094 exam questions frequently feature detailed scenarios and practical problem-solving exercises that directly mirror industry challenges. Engaging with these NS0-094 sample sets allows you to effectively manage your time and pace yourself, giving you the ability to finish any NetApp Hardware Support Engineer Professional Exam practice test comfortably within the allotted time.

Question # 1

At what stage is a write acknowledged to a client?

A.

when the write is present in the local node RAM and NVRAM

B.

when the write has been flushed to disk

C.

when the write is present in the NVRAM on the local node and its HA partner

D.

when the write has been flushed from NVRAM to RAM

Question # 2

Users are reporting slowness when accessing certain volumes with extremely high-performance requirements via NFSv3 on a four-node switched NetApp ONTAP cluster. Other volumes on the same cluster are behaving normally. Investigation reveals that there is a high amount of throughput recorded for the cluster LIFs.

What action enables you to determine which volumes are affected?

A.

View the active CIFS sessions on the cluster to determine the affected workloads.

B.

Check the NFS file locking lease period for the affected volumes.

C.

Review NFS export policies to ensure that client subnets are listed for the affected volumes.

D.

View the NFS connected client information and review the “Remote-Reqs” counter.

Question # 3

Which RAID type provides protection against three disk failures?

A.

RAID DP

B.

RAID-TEC

C.

RAID 5

D.

RAID 4

Question # 4

In the latest MANAGEMENT LOG AutoSupport message, you try to inspect the ENVIRONMENT section but find it empty.

In which section of AutoSupport can you find the reason?

A.

AUTOSUPPORT-BUDGET.XML

B.

HEADERS

C.

AUTOSUPPORT-HISTORY.XML

D.

MANIFEST.XML

Question # 5

Which two statements are correct when describing L1 and L2 Watch Dog Resets (WDR)? (Choose two.)

A.

L2 WDR requests creation of a core dump before reset.

B.

L1 WDR is initiated after 0.5 seconds from the event.

C.

L1 WDR performs a soft reset.

D.

L2 WDR is initiated after 2 seconds from the event.

Question # 6

You have upgraded your cluster from ONTAP 9.5 software to ONTAP 9.7 software. After the upgrade, you notice that the upgrade causes issues. You decide to revert to ONTAP 9.5 software.

Which revert step is allowed?

A.

Revert to ONTAP 9.5 software with the netboot procedure.

B.

Revert from ONTAP 9.7 software to ONTAP 9.5 software by using the boot backup procedure.

C.

Revert directly from ONTAP 9.7 software to ONTAP 9.5 software.

D.

Revert from ONTAP 9.7 software to ONTAP 8.6 software and then to ONTAP 9.5 software.

Question # 7

In maintenance mode, which of the following commands shows disk ownership?

A.

sysconfig –v

B.

disk show –v

C.

aggr status

D.

storage show disk –p

Question # 8

A node has failed.

Which two conditions must be met for an automatic takeover to be triggered? (Choose two.)

A.

The combined utilization of both nodes must be less than 100%.

B.

The cluster network must be available.

C.

Mailbox disks must be reachable.

D.

NVRAM must be synchronized.

Question # 9

When you add a new disk to an ONTAP 9.1 system, you see an error that the disk “has raid label with version (16), which is not within the currently supported range (14-15).” What is one possible cause of this error?

A.

The disk is a non-zeroed spare.

B.

The disk firmware is too new for ONTAP software.

C.

The disk needs to be assigned to the new system.

D.

The disk was in a system with a newer version of ONTAP software

Question # 10

You notice the following system alert during a routine check of a four-node NetApp ONTAP cluster:

Alert ID: SwitchIfDead_Alert

Resource: Slot: 0 Port: 55 100G - Level

Severity: Major

Probable Cause:

The interface broadcomswitch-011/Slot: 0

Port: 55 100G - Level is up, but it is

not passing unicast traffic.

Possible Effect:

The lack of transmit or receive traffic

reported by the switch can indicate

issues with port-level or switch-level

data packet forwarding.

Corrective Actions:

1) Check interface counters and neighbor

discovery information to verify the

port's activity.

2) Check cluster and switch health status.

The customer confirms that the cables are connected correctly and interface LEDs on the switches are on.

What is the next step in troubleshooting this issue?

A.

Remove the cluster ports from the cluster IPspace and cluster broadcast domain, and delete the health alerts.

B.

Verify the configuration of the switchports with the output of RCF Configurator.

C.

Bounce the cluster interconnect ports on the ONTAP cluster nodes that are reporting this alert.

D.

Revert the ONTAP software upgrade to see if the alert disappears.

Go to page: