Last Update 8 hours ago Total Questions : 66
The VMware HCI Master Specialist content is now fully updated, with all current exam questions added 8 hours ago. Deciding to include 5V0-21.21 practice exam questions in your study plan goes far beyond basic test preparation.
You'll find that our 5V0-21.21 exam questions frequently feature detailed scenarios and practical problem-solving exercises that directly mirror industry challenges. Engaging with these 5V0-21.21 sample sets allows you to effectively manage your time and pace yourself, giving you the ability to finish any VMware HCI Master Specialist practice test comfortably within the allotted time.
Due to the success of the recently deployed developer-only private cloud solution, a company has a new requirement to at least double the usable capacity in their all-flash vSAN cluster.
The vSAN cluster is deployed into a co-located datacenter that is owned by a third-party hosting company. The hosting company charges a fixed monthly cost for rack space and power consumption. The service owner has been given a limited budget for additional hardware purchases, but not for on-going co-location costs.
The current vSAN cluster has the following configuration:
* 10 vSAN Nodes with 2 CPUs (20 cores), 512 GB RAM
* 1 Disk Group per vSAN node
- 1 x 400 GB
- 4 x 1.8 TB
* De-duplication and Compression is enabled.
* vSAN Capacity is currently:
- Total: 72 TB
- Usable: ~40 TB (FTT1/RAID1) and ~60 TB (FTT1/RAID5).
As a result of any action taken, the service owner would like to ensure that overall availability of the vSAN cluster is increased.
Which two recommendations meet the requirement to increase capacity while maintaining service availability? (Choose two.)
A cache disk failure marked a vSAN disk group as failed, and the data is being rebuilt on other disk groups.
Which action should the vSAN administrator take to reduce the negative impact on the VMs?
Which three steps are required to decommission a stretched cluster and convert it to a standard vSAN cluster? (Choose three.)
An administrator is tasked with sharing storage from one vSAN cluster to another vSAN cluster. SPBM management must be preserved end-to-end, and the policy must be applied by the source vSAN cluster which is storing the data. Both vSAN clusters are managed by the same vCenter server.
What should the administrator configure?
A vSAN policy has been configured with Erasure Coding on a vSAN stretched cluster.
Which RAID level and FTT setting have been specified?
An architect intends to use the Primary Level of Failures To Tolerate (PFTT) to calculate the minimum number of required hosts for a vSAN cluster.
Which calculation model should be used?
An architect is reviewing a vSAN cluster that has an unbalanced cluster configuration.
Which behavior will the architect observe?
An administrator is planning to change a vSAN Storage Policy to apply a Failures To Tolerate (FTT) of 2, using RAID-6.
What is the minimum number of vSAN nodes required?
An architect is currently working with a customer to transform their existing ESXi hosts to vSAN nodes. The customer expressed the following requirements.
• First phase will transform 50% of the hosts to a hybrid vSAN nodes.
• Second phase will transform the remaining 50% hosts to an All-Flash vSAN nodes.
The following constraint exists:
• Each host has a 4-port x 1 GbE network interface.
Which two recommendations should the architect make to align with the customer ' s requirements? (Choose two.)
A customer is planning to migrate their physical Microsoft SQL Server clustered workloads to vSAN enabled vSphere clusters.
The following requirements must be met:
* Each MSSQL cluster is made up of 3 nodes
* Highest possible availability against node failures
* Some of the vSAN clusters will only consume storage
What should the architect recommend?
