You'll find that our H19-371_V1.0 exam questions frequently feature detailed scenarios and practical problem-solving exercises that directly mirror industry challenges. Engaging with these H19-371_V1.0 sample sets allows you to effectively manage your time and pace yourself, giving you the ability to finish any HCS-Pre-sales-Digital Power V1.0 practice test comfortably within the allotted time.

Question # 91

The UPS system is equipped with 32 12V batteries, and the float voltage set by the UPS is ( ).

A.

432V

B.

451V

C.

540V

D.

564V

Question # 92

The cell of Huawei Smartli lithium battery is ()

A.

NCM

B.

LFP

C.

Ni-Cd

Question # 93

Fusionllodule2000 UPS is listed, configuration (

A.

Integrated UPS cabinet

B.

Integrated power distribution cabinet

C.

Precision power distribution cabinet

Question # 94

The NetEco6000 management system can manage the devices inside the FusionModule and outside the module at the same time. In the default recommended solution, the

devices inside the FusionModule use the ( ) collector to access the device, and the devices outside the module use the ( ) collector. to access the device?

A.

ECC500, ECC500

B.

ECC500, ECC800

C.

ECC800, ECC500

D.

ECC800, ECC800

Question # 95

The fire-fighting measures that can be used in the Class A computer room include:

A.

Gas Fire Extinguishing System

B.

Water mist fire extinguishing system

C.

Automatic sprinkler system

D.

All of the above

Question # 96

When the Netfco management system adopts the single 6RH1585 server, it can support the maximum access (10,000 test points, so as to realize the centralized management of multiple data centers?

A.

20

B.

40

C.

50

D.

100

Question # 97

The temperature control products used in the FusionModule1000A V2R3 version T solution are:

A.

20kW inverter half-cabinet row level

B.

25kW half cabinet row level

C.

25kW inverter half-cabinet row level

D.

20kW half cabinet row level

Question # 98

The output power factor of UPS5000-E is as high as ( ), which can carry 11% more load than traditional UPS.

A.

1

B.

0.9

C.

0.95.

Question # 99

What is the range of the number of battery cabinets in the FusionModule800 module?

A.

0 〜 4

B.

0 〜 3

C.

0 〜 2

D.

0 〜 1

Question # 100

The FusionModule2000 battery is listed in the scene, supports up to several battery cabinets (

A.

4

B.

6

C.

2

D.

8

Question # 101

How many cabinets can a single row of FusionModule2000 support? (

A.

48

B.

12

C.

36

D.

24

Question # 102

When the operating temperature of the UPS2000-A is too high ().

A.

Switch to bypass mode

B.

Switch battery mode

C.

Stop output, load power off

D.

no action

Question # 103

UPS2000-G 6~20kVA maximum support () parallel, good scalability.

A.

0

B.

2

C.

3

D.

4

Question # 104

The minimum ambient temperature used by FusionModule800 is ( )

A.

-20°C

B.

0°C

C.

-40°C

D.

Below -40°C.

Question # 105

The wrong description about the reliability of NetCol5000-C row-level air conditioner is:

A.

It adopts dual power supply, and the two power supply adopts automatic switching mode

B.

Operators, large data centers such as large corporate headquarters prefer this type of air conditioner, and small and medium-sized enterprises are more likely to use NetCol5000-A air conditioners

C.

Multi-fan air supply: online maintenance is possible

D.

Cannot be used in scenarios without raised floor, because condensate drainage cannot be connected to the pipe