You'll find that our H19-371_V1.0 exam questions frequently feature detailed scenarios and practical problem-solving exercises that directly mirror industry challenges. Engaging with these H19-371_V1.0 sample sets allows you to effectively manage your time and pace yourself, giving you the ability to finish any HCS-Pre-sales-Digital Power V1.0 practice test comfortably within the allotted time.

Question # 181

Huawei ' s main temperature control solution for small and medium-sized computer rooms is:

A.

Row-level chilled water with micro-modules

B.

Room-level air cooling solution

C.

Row-level air cooling with micro-modules

D.

Room-level chilled water solution

Question # 182

In the FusionModule2000 configurator, what are the common cabinet specifications (

A.

600*1200*2000

B.

800*1200*2000

C.

600*1200*2200

D.

800*1200*2200

Question # 183

UPS5000-E-500K Regarding efficiency, which of the following options is correct? ()

A.

Efficiency 96%

B.

Efficiency 94%

C.

ECO mode 99%

D.

ECO mode 98%

Question # 184

When selecting UPS cables, the problems to be considered are ()

A.

UPS-related current rating

B.

The rated working voltage and rated insulation voltage of the cable

C.

Voltage drop across the cable path

D.

Number of parallel cables

Question # 185

Huawei 25KW half-cabinet inverter air-cooled air conditioner, the following description is correct (multiple choice)

A.

The capacity algorithm for a single air conditioner with UPS is 1.2* 1.732*full load current*380*0.8/0.9

B.

The capacity algorithm for a single air conditioner with UPS is 1.2*5* 1.732*full load current*380*0.8/0.9

C.

The UPS capacity requirement of a single air conditioner is 15.8kVA. If you configure UPS5000E, you need to configure at least one 25kVA power module

D.

The UPS capacity requirement of a single air conditioner is 79.0kVA. If you configure UPS5000E, you need to configure at least two 40kVA power modules

E.

If a group of air conditioners is connected to a set of UPS systems, then it is necessary to multiply the number of air conditioners running at the same time on the basis of a single UPS, such as 5+1 cold backup configuration, then it needs to be

based on the capacity requirement of a single air conditioner UPS Multiply by 5 to get total UPS capacity requirement, configure

Question # 186

80kW T load, the UPS system with 80kVA can meet the basic needs.

A.

True

B.

False

Question # 187

Huawei ' s modular computer room supports cold aisle and hot aisle. True or False.

A.

True

B.

False

Question # 188

The Huawei Configurator can automatically configure the cable specifications and lengths from the head cabinet to the IT cabinet. ( ).

A.

True

B.

False

Question # 189

Huawei Neteco network management supports mobile APP management

A.

True

B.

False

Question # 190

FusionModule800 connecting pipes within 30m does not need to charge refrigerant on site?

A.

True

B.

False

Question # 191

The backup time of UPS system is generally within 30min, so it is more reasonable to use the constant current method to calculate the battery capacity.

A.

True

B.

False

Question # 192

FusionModule1000A V2R3 version supports custom VESDA system

A.

True

B.

False

Question # 193

The battery can meet customer needs regardless of the brand, as long as it depends on the capacity. ( ).

A.

True

B.

False

Question # 194

Huawei ' s prefabricated power modules contain the following configurations ( ).

A.

Feeder cabinet

B.

Compensation Cabinet

C.

UPS

D.

Transformer

Question # 195

The NeEco management system supports remote notification of alarms through SMS, email, etc., prompting users to deal with alarms as soon as possible.

A.

True

B.

False