You'll find that our H19-371_V1.0 exam questions frequently feature detailed scenarios and practical problem-solving exercises that directly mirror industry challenges. Engaging with these H19-371_V1.0 sample sets allows you to effectively manage your time and pace yourself, giving you the ability to finish any HCS-Pre-sales-Digital Power V1.0 practice test comfortably within the allotted time.

Question # 136

The characteristics of the compressor used by Huawei NetCol5000-A include: (multiple choice)/

A.

The highest volumetric efficiency, low noise and low vibration

B.

No reciprocating motion, few moving parts, high reliability

C.

International famous brand, long life, high reliability

D.

Safe operation under 3000V voltage

Question # 137

What are the certifications of FusionModule500 & FusionModule800? (

A.

Air conditioner: CCC/CE/REACH/ROHS

B.

Integrated cabinet: CE/REACH/ROHSО

C.

Air conditioner: REACH/ROHS

D.

Integrated cabinet: CE/CCC/ROHS

Question # 138

In a single cabinet configuration scenario, which of the following scenarios can be configured? (

A.

Fusionlodule2000

B.

FusionModule800

C.

FusionModule5000

D.

Fusionlodule500

Question # 139

Regarding the characteristics of the FusionModule2000 row-level air conditioner, which of the following descriptions is wrong? ( )

A.

Only 42KW supports wet film humidification function

B.

Both 25KW and 42KW support wet film humidification function

C.

Both 25KW and 42KW support light-load dehumidification

function

Question # 140

Which modules can be hot-replaced online in UPS5000-E (50kVA power module)? ( )

A.

Power Module

B.

Control Module

C.

Bypass Module

D.

Power distribution module:

Question # 141

In UPS5000S, the adjustable range of the number of battery cells in a single group is

A.

Sections 30 to 44

B.

Sections 30 to 42

C.

Sections 30 to 46

D.

Sections 30 to 48

Question # 142

12V battery cell, which of the following voltages are acceptable normal use voltages: ()

A.

13V

B.

14.1V

C.

14.52V

D.

10.02V

Question # 143

Which options are there for the video frame storage time of FusionModule500 & FusionModule800?

A.

a week

B.

a month

C.

three months

Question # 144

UPS5000-E is a high-efficiency UPS. Which of the following statements is correct? ( )

A.

The efficiency can reach 94% with 20% load

B.

The efficiency can reach 96% with 40% load

C.

Efficiency up to 96%

D.

The efficiency can reach 95% with 20% load.

Question # 145

Regarding the overload capacity of UPS5000-E, which of the following statements is correct?

A.

Inverter 110% overload for 120 minutes

B.

Bypass 135% overload long-term operation

C.

Inverter 110% overload for 60 minutes

D.

Bypass 135% overload for 120 minutes

Question # 146

Regarding the micro-module and fire protection system, which of the following are true? (multiple choice)

A.

When a fire alarm occurs in the channel, the ECC800 provides an alarm to the data center fire host by providing passive thousand-contact signals.

B.

ECC800 can control skylight rollover and fire sprinkler to spray fire gas

C.

The data center fire host provides passive dry contact signals to the ECC800, and the ECC800 can identify the fire alarm information

D.

ECC800 controllable module and building fire control linkage

Question # 147

The NetEco6000 management system can provide the temperature cloud map function to realize the identification of cold and hot spots in the computer room. How many layers of temperature maps does the temperature cloud map support? ( ).

A.

Single layer

B.

Double layer

C.

Three floors

D.

Fourth floor

Question # 148

What are the three-in-one access control methods of Fusionmodule2000 ( )

A.

Password

B.

Fingerprints

C.

Swipe your card

Question # 149

What are the i3 features of FusionModule2000 V3.0 version?

A.

iCooling

B.

iPower

C.

iManager

Question # 150

Which of the following functions does the PDU8000 precision power distribution cabinet have: (multiple choice)

A.

Power distribution function of data center micro-module (cabinet)

B.

The protection function of the lower line and equipment of the precision power distribution cabinet

C.

Main circuit and sub-circuit metering function of precision power distribution cabinet

D.

Abnormal alarm function of main circuit and sub-circuit of precision power distribution cabinet

E.

The precision power distribution cabinet supports SNMP and MODBUS communication, which can transmit information to the intelligent monitoring

system.