Summer Sale Special Limited Time 70% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: buysanta

Exact2Pass Menu

Nutanix Certified Master - Multicloud Infrastructure (NCM-MCI) 5.15

Last Update 23 hours ago Total Questions : 107

The Nutanix Certified Master - Multicloud Infrastructure (NCM-MCI) 5.15 content is now fully updated, with all current exam questions added 23 hours ago. Deciding to include NCM-MCI-5.15 practice exam questions in your study plan goes far beyond basic test preparation.

You'll find that our NCM-MCI-5.15 exam questions frequently feature detailed scenarios and practical problem-solving exercises that directly mirror industry challenges. Engaging with these NCM-MCI-5.15 sample sets allows you to effectively manage your time and pace yourself, giving you the ability to finish any Nutanix Certified Master - Multicloud Infrastructure (NCM-MCI) 5.15 practice test comfortably within the allotted time.

Question # 11

For several days, an administrator notices the following alerts:

• CVM NIC Speed Low Warning Alerts

• Warning Alerts of CVM NIC not performing at optimal speed

• CVM is disconnected from the network Critical Alert

• Network Visualization page shows excessive dropped packets on CVM/Host

Which steps should be taken to determine which problem should be addressed first?

A.

• Access the Hardware Page to verify resources are available

• Analyze ail CVM Speed Alerts in the Alerts/Events page

• Analyze output for the network and interface properties and connectivity issues

B.

• Verify Host/CVM connectivity on the Network Visualization page

• Use to verify the bridge and bond configuration

• Review alerts/events page for the CVM disconnected error

C.

• Review Alerts page for NIC speed alerts and alert timing

• Analyze the genesis.out log file for process failures

• Assess the NIC properties in the Network Visualization > Host Properties page

D.

• Restart networking services on the CVM

• Determine the current configuration of the affected CVM via output

• Access the Alerts/Events page for the CVM network connection failures

Question # 12

An administrator is trying to correct high cluster IOPs and Cluster Controller Latency. Networking is the suspected issue.

Which networking parameters should be configured in the Nutanix cluster?

A.

Bond State and network latency

B.

Number of NICs connected and network latency.

C.

Number of NICs connected and frame size

D.

Number of NICs connected and bond state.

Question # 13

An administrator has an existing Nutanix seven-node cluster running at RF2 that must be changed to have the following capabilities:

• RF3 set for the cluster

• Performance tier deduplication

What is the minimum memory needed on the CVMs to allow for these capabilities?

A.

24GB

B.

28GB

C.

32GB

D.

20G?

Question # 14

An administrator recently added VLAN 205 CRM in Prism Element. The workloads attached to the associated NICs are unable to establish network connectivity.

Which Layer 2 protocol allows the administrator to troubleshoot this issue from Prism Element?

A.

HDLC

B.

SUP

C.

LACP

D.

LLDP

Question # 15

An administrator is concerned that Prism will be inaccessible if Active Directory is unable to process logins. Which method should the administrator use to access the cluster in the event of this type of outage?

A.

Manage the cluster by using the " nutanix " user on the Prism leader CVM

B.

Create and use an emergency local account on the cluster

C.

Deploy an Active Directory server locally on the cluster

D.

Manage the cluster remotely by downloading ncli to a remote workstation

Question # 16

A customer has a Nutanix cluster with 10Gb connectivity via switch fabric extenders. The administrator receives NCC health check errors of latency greater than 200ms.

Which action should the administrator take to resolve the NCC errors?

A.

Replace the switch fabric extenders with 10G line rate switches

B.

Upgrade NCC and increase the CVM memory by 4Gb

C.

Add 2 additional 10G uplinks from the switch fabric extenders per node

D.

Upgrade NCC and increase the vCPU of the CVM

Question # 17

An administrator is notified that a bare metal database server is down. This database server is being served storage using a Nutanix Volume Group. Upon investigating, the administrator finds that the disks in the database server that map to the vDisks in the volume group have gone offline.

What is causing this issue?

A.

The Volume Group Load Balancer has been disabled.

B.

Port 9443 is blocked in the server firewall.

C.

Port 3260 has been blocked in the server firewall.

D.

A CVM serving the Volume Group has gone offline.

Question # 18

An administrator is deploying several new application VMs to a Nutanix cluster. The application is very transactional with a 28/72 random, read/write ratio.

What should the administrator do?

A.

Add a minimum of four SSDs to each node to ensure all writes go to the SSDs.

B.

Add a minimum of four virtual disks to each VM, and aggregate them on guest OS level.

C.

Add one large SSD to each node and enable Flash Mode for the VMs.

D.

Add one large virtual disk to each VM. and use it for all application data.

Question # 19

An administrator needs to relocate an AHV cluster to a new datacenter during a maintenance window. The cluster will use the same IPs in the new datacenter.

Which two steps should be taken to prepare for this task? (Choose two.)

A.

Stop all Nutanix Files clusters

B.

Relocate the linked LDAP servers

C.

Shut down all user VMs in the cluster

D.

Reconfigure IPMI for the new datacenter

Question # 20

An administrator needs to deploy an application with a large amount of data connected via Nutanix Volumes.

Which two actions should the administrator take when designing the Volume Group? (Choose two.)

A.

Use multiple subnets for iSCSI traffic

B.

Enable RSS (Receive Side Scaling)

C.

Enable thick provisioning on the Volume Group(s)

D.

Distribute workload across multiple virtual disks

Go to page: