Spring Sale Special Limited Time 70% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: buysanta

Exact2Pass Menu

HCS-Pre-sales-Digital Power V1.0

Last Update 13 hours ago Total Questions : 653

The HCS-Pre-sales-Digital Power V1.0 content is now fully updated, with all current exam questions added 13 hours ago. Deciding to include H19-371_V1.0 practice exam questions in your study plan goes far beyond basic test preparation.

You'll find that our H19-371_V1.0 exam questions frequently feature detailed scenarios and practical problem-solving exercises that directly mirror industry challenges. Engaging with these H19-371_V1.0 sample sets allows you to effectively manage your time and pace yourself, giving you the ability to finish any HCS-Pre-sales-Digital Power V1.0 practice test comfortably within the allotted time.

Question # 166

What is the cabinet depth of Huawei Micro Module 2000? ( )

A.

1000mm

B.

1100mm

C.

1200mm

D.

1500mm

Question # 167

The root standard stipulates that the voltage drop of the AC cable should be controlled within 3%. It is recommended that the voltage drop of the AC cable should be controlled within ( ) when designing the UPS system.

A.

0.02

B.

0.05

C.

0.03

D.

0.01

Question # 168

When the distance between the outdoor unit and the seaside is 0.5km~3.7km, you need to configure the () outdoor unit

A.

Class d

B.

Class a

C.

class c

D.

class b

Question # 169

Regarding the monitoring software NetEco1000U, the following statements are correct ()

A.

Monitor the working status of the UPS in real time and operate the UPS

B.

Support USB, SNMP, MODUBUS network communication

C.

Email alarm, SMS alarm and other alarm reporting functions

D.

SMS alarm needs to be equipped with SMS cat

E.

Provided for free, download and use the answer from the Huawei Support website

as needed

Question # 170

NetEco6000 management system uses the above security mechanisms to ensure network security and prevent business sensitive data leakage? ()

A.

Permission Control

B.

Transmission Security

C.

Storage Security

D.

None of the above is true

Question # 171

iBattery intelligent battery management, which can monitor the parameters of a single battery in detail. What are the specific parameters? (Multiple choice)

A.

Current

B.

Voltage

C.

Internal resistance

D.

Temperature

Question # 172

The NetEco management system combines the operation and maintenance experience of Huawei I and the process department to launch an electronic remote maintenance module to help the operation and maintenance personnel to complete the daily operation and inspection of the computer room. Which of the following functions can be achieved: (multiple choice)

A.

Support the formulation of inspection plans, track inspection progress,

B.

Support custom documents for inspection content and inspection routes

C.

With the help of mobile App, you can receive inspection tasks and record the inspection process in vain

D.

Support the generation of road inspection reports in the computer room

Question # 173

The NetCol 8000-C room-level chilled water intelligent temperature control product has parts that can be plugged and maintained online, which can greatly reduce the time for parts replacement.

()

A.

Main control module

B.

Auxiliary source module

C.

Electric heating

D.

Fan

Question # 174

Among the following models, the one with the widest input frequency range is ().

A.

NXR

B.

UPS5000-A

C.

Galaxy5000

D.

9390

Question # 175

The following functions belong to the Fusionmodule2000 controller (ECC800) ( )

A.

Access Control

B.

Alarm Management

C.

Alarm system linkage

Question # 176

Which of the following functions or components does the UPS6000-E (50kVA power module) come standard with? ( )

A.

Dry contact communication card

B.

Parallel function

C.

SNMP function

D.

Bus synchronization control function

Question # 177

What functions does the iCooling feature of FusionModule2000 V3.0 include? ( )

A.

AI self-optimization algorithm, air conditioner saves 8% of energy

B.

Temperature cloud map and air conditioning linkage

C.

Refrigerant capacity alarm function

D.

Refrigeration system visibility

Question # 178

Which of the following statements are true about the iBattery battery management system? ()

A.

iBattery can manage battery

B.

iBattery can be connected to UPS

C.

iBOX can be powered by DC 48V or POE

D.

The iBat signal is wirelessly connected to the iBOX

Question # 179

UPS system battery intelligent management can fully extend battery life. Which of the following functions does UPS2000-G-(6K 20K) battery management support? () (multiple choice)

A.

Smart Sleep

B.

Automatic floating charge conversion

C.

Temperature supplement

D.

The number of battery cells is adjustable

Question # 180

Which of the following functions or components does the UPS5000-E (50kVA power module) come standard with? ( )

A.

SNMP function

B.

Dry contact communication card

C.

Parallel function

D.

Bus synchronization control function

Go to page: