You'll find that our CDCS exam questions frequently feature detailed scenarios and practical problem-solving exercises that directly mirror industry challenges. Engaging with these CDCS sample sets allows you to effectively manage your time and pace yourself, giving you the ability to finish any EXIN EPI Certified Data Centre Specialist practice test comfortably within the allotted time.

Question # 21

What is the first step in the design stage of the data center life cycle?

A.

Select vendors

B.

Do a design validation

C.

Define the scope of the project

D.

Freeze the design

Question # 22

You need to install a highly sensitive fire detection system. The data center has a high airflow rate. Which system should you recommend?

A.

Dry pipe sprinkler system

B.

Ionization smoke detector

C.

Photoelectric smoke detector

D.

VIEW (Very Early Warning) smoke detector

Question # 23

What is the advantage of using Multi-fiber Push-On (MPO) connectors?

A.

No advantage, cannot be used with OM4 fiber

B.

Allows a single connector with multiple fibers running parallel, enabling easy upgrade to 40–100 Gbit/s

C.

Made of high-quality materials, reusable without risk

D.

Very flexible, can be used for both copper and optical fiber

Question # 24

From the options indicated, what is the correct starting point for the raised floor installation?

A.

Point A

B.

Point B

C.

Point C

D.

Point D

Question # 25

In which stage of the data center life cycle does testing and commissioning take place?

A.

Design stage

B.

Implement stage

C.

Operate/optimize stage

D.

Retire stage

Question # 26

A computer room with a raised floor has been designed with racks in a hot/cold aisle setup.

What should you recommend for the placement of down-flow air conditioners?

A.

Air conditioners perpendicular to (at the end of the row of) the Cold-Aisle

B.

Air conditioners perpendicular to (at the end of the row of) the Hot-Aisle

C.

Air conditioners should always be placed at both sides of each row of racks

D.

Air conditioner placement has no influence on cooling effectiveness and efficiency. Hence, they can be placed at any convenient location.

Question # 27

A 5kW (power consumption) server keeps crashing with the message ' temperature too high ' .

The intake temperature is measured at 25 °C/77 °F and a relative humidity (RH) level of 50%.

The exhaust temperature is 29 °C/84 °F and 45% RH.

The raised floor is providing an adequate amount of CFM/CMH at a reasonable velocity.

The pressure under the raised floor is approximately 25 Pa/0.1 inch H₂O.

Analyze the situation and indicate what the most likely cause is for this server to crash.

A.

Dust inside the server causing issues with convection-based heat transfer

B.

The exhaust temperature is exceeding the ASHRAE recommended values

C.

The raised floor pressure is too low and/or the raised floor tile % opening is not adequate

D.

No cause could be determined as the CFM/CMH of the air conditioning equipment is not stated

Question # 28

The logical overview of the data center looks as pictured below. To what TIA-942 Rating is this design made based on electrical only?

A.

Rating-4

B.

Rating-3

C.

Rating-2

D.

Rating-1

Question # 29

What is the focus of the Open Compute Project (OCP)?

A.

Saving energy, materials, and costs

B.

Standardizing equipment only for hyperscale data centers

C.

Developing an open-source operating system

D.

Making cloud computing more accessible

Question # 30

In which stage of the data center life cycle does commissioning take place?

A.

Retire

B.

Operate/optimize

C.

Implement

D.

Design