BICSI Data Center Design Consultant - DCDC

Last Update 17 hours ago Total Questions : 158

The BICSI Data Center Design Consultant - DCDC content is now fully updated, with all current exam questions added 17 hours ago. Deciding to include DCDC-003.1 practice exam questions in your study plan goes far beyond basic test preparation.

You'll find that our DCDC-003.1 exam questions frequently feature detailed scenarios and practical problem-solving exercises that directly mirror industry challenges. Engaging with these DCDC-003.1 sample sets allows you to effectively manage your time and pace yourself, giving you the ability to finish any BICSI Data Center Design Consultant - DCDC practice test comfortably within the allotted time.

Question # 11

What is the difference between a raised floor and a solid floor?

A.

Raised floor allows for better airflow and cable management

B.

Solid floor allows for better cooling efficiency and higher load capacity

C.

Raised floor is cheaper and easier to install

D.

Solid floor is more flexible and adaptable to changing needs

Question # 12

What is the minimum separation distance of underground telecommunications and utility cabling in same route?

A.

2 feet minimum along entire route

B.

6 feet minimum along entire route

C.

no need for separation as long as they are enclosed in different conduit systems.

D.

none of the above

Question # 13

what are 2 typical printer manufacturer environmental criteria?

A.

humidity and temperature

B.

lighting and sound level

C.

radioactivity measurement and electromagnetic interference

D.

electrical conductivity and soil contamination

Question # 14

What is an automatic static transfer switch used for?

A.

Switching between multiple utility power sources

B.

Switching between utility and generator power sources

C.

Switching between different generator power sources

D.

Switching between AC and DC power sources

Question # 15

What is the acceptable dew point level in a data center according to TIA-942?

A.

60 degrees

B.

65 degrees

C.

69.8 degrees

D.

75 degrees

E.

80 degrees

Question # 16

What is the acceptable rate of temperature change per hour in a data center according to TIA-942?

A.

5 degrees

B.

7 degrees

C.

9 degrees

D.

12 degrees

E.

15 degrees

Question # 17

what are the two rooms that may require 2 exits?

A.

the electrical Room and battery room

B.

Equipment Room and Security Rooms

C.

Mechanical Room and Electrical

D.

Computing rooms And Storage rooms

E.

Water Supply Rooms

Question # 18

What room should have direct access to the computer room?

A.

Break room

B.

Server room

C.

Network Operations Center (NOC)

D.

Administrative office

Question # 19

What is the recommended amount of fuel supply needing to be available to a class F3 data center?

A.

24 hours

B.

48 hours

C.

72 hours

D.

96 hours

Question # 20

where should printers be located

A.

beside high traffic areas

B.

near equipment that has active air flow to cool them down

C.

in a dedicated print room with dedicated air handling system

D.

placed outdoor, away from building facilities