You'll find that our DCDC-003.1 exam questions frequently feature detailed scenarios and practical problem-solving exercises that directly mirror industry challenges. Engaging with these DCDC-003.1 sample sets allows you to effectively manage your time and pace yourself, giving you the ability to finish any BICSI Data Center Design Consultant - DCDC practice test comfortably within the allotted time.

Question # 31

What are the 3 types of Authentication for access control?

A.

Type 4 - What you possess

B.

Type 5 - What you desire

C.

Type 6 - What you create

D.

Type 1 - What you have

Type 2 - What you know

Type 3 - What you are

Question # 32

What is the recommended amount of fuel supply to be available to a class F0 data center?

A.

12 hours

B.

24 hours

C.

48 hours

D.

None - No requirements

Question # 33

According to NEB, what is the recommended rate of temperature change per hour in a data center?

A.

36 degrees

B.

45 degrees

C.

54 degrees

D.

63 degrees

E.

72 degrees

Question # 34

What is the recommended range of temperature for a data center?

A.

18-22°C (64-72°F)

B.

20-24°C (68-75°F)

C.

22-26°C (72-79°F)

D.

24-28°C (75-82°F)

E.

26-30°C (79-86°F)

Question # 35

How do you calculate the thermal load of the lighting system inside a data center?

A.

Rated power * .01

B.

IT load * .01

C.

Rated power * .02

D.

IT load * .02

E.

Rated power * .05

Question # 36

What is the first preference regarding utility service, class F4?

A.

At least two circuits from one substation, same path

B.

One circuit from one substation, separate paths

C.

At least two circuits from two separate substations, diverse substation power grids and separate paths

D.

At least one circuit from two separate substations, different voltage levels

Question # 37

what is the best practice performance metric to gauge thermal compliance for ASHRAE and NEBS for a given data center

A.

Temperature-Humidity Index (THI)

B.

Airflow Efficiency Ratio (AFER)

C.

Power Usage Effectiveness (PUE)

D.

Computational Fluid Dynamics (CFD) modeling

Question # 38

Where is temperature typically measured in a data center HVAC system?

A.

At the CRAC unit exhaust

B.

At the CRAC unit inlet

C.

At the server rack inlet

D.

At the server rack exhaust

Question # 39

Where should power cable be ran in an access floor?

A.

Hot aisle

B.

Cold aisle

C.

Above the access floor

D.

Below the access floor

Question # 40

What ' s conservative ' hydrogen maximum flow rate per minute for battery.

A.

500 cm/m²

B.

21 cm/m²

C.

61 cm/m²

D.

None of these answer