You'll find that our FlashArray-Implementation-Specialist exam questions frequently feature detailed scenarios and practical problem-solving exercises that directly mirror industry challenges. Engaging with these FlashArray-Implementation-Specialist sample sets allows you to effectively manage your time and pace yourself, giving you the ability to finish any Pure Certified FlashArray Implementation Specialist (FAIS) Exam practice test comfortably within the allotted time.

Question # 4

An Implementation Engineer performing an inventory of hardware for an NDU from an FlashArray//X70R2 to an FlashArray //X90R3 and discovers c complete FlashArray//X90R3 was shipped in place of an NDU kit. What is the minimum hardware the Implementation Engineer should use from this array to complete the NDU?

A.

Controllers

B.

Controller and power supplies

C.

Controller and NVRAM

Question # 5

In a situation where iSCSI cards need to be re-used during a controller upgrade, which is a valid transfer path?

A.

XR2 > XR3

B.

M > XR2/3

C.

M > XR2

Question # 6

Before proceeding with a controller upgrade, phonehome logs must be sent. What command will verify that the logs have been sent?

A.

purearray phonehome --check

B.

purearray phonehome --list

C.

purearray phonehome --status

Question # 7

If drives need to be relocated within an array for an XFORM upgrade, when should this be completed?

A.

During the upgrade

B.

After upgrade is completed

C.

The following day

Question # 8

What command can be used to identify interface status?

A.

purenetwork list

B.

purenetwork list --all

C.

purenetwork list --eth

Question # 9

When transforming an array from SAS to NVMe with the Evergeen XFORM upgrade, when should a swing shelf be installed?

A.

When the chassis is populated with two data packs

B.

When there is insufficient free space to evac capacity.

C.

When the array is half populated with Flash Modules

Question # 10

An Implementation Engineer is onsite to install a new DFM data pack (DP) to CH0.BAY10-CH0.BAY19 of a FlashArray.

After adding the drives to the chassis, which command should the Implementation Engineer run to verify if the new DP is in a wide write group?

A.

find_drive.py

B.

puredb list drives

C.

puredrive list --pack CH0.BAY10