You'll find that our FlashArray-Implementation-Specialist exam questions frequently feature detailed scenarios and practical problem-solving exercises that directly mirror industry challenges. Engaging with these FlashArray-Implementation-Specialist sample sets allows you to effectively manage your time and pace yourself, giving you the ability to finish any Pure Certified FlashArray Implementation Specialist (FAIS) Exam practice test comfortably within the allotted time.

Question # 31

After rebooting a controller, which command should an Implementation Engineer run to verify all the Purity services have started successfully?

A.

pureadm status --all

B.

pureadm list --status

C.

pureadm list

D.

purecluster status

Question # 32

What is the required PSU wattage for a FlashArray// X70R2/R3 or X90R2/R3 array?

A.

1200W

B.

1300W

C.

1600W

Question # 33

At the completion of an upgrade, which command is used to send phonehome logs?

A.

purelogs --send-all

B.

purearray phonehome --send-logs

C.

purearray phonehome --send-today

Question # 34

Which command should an Implementation Engineer use to allow Support access to an array?

A.

purearray connect --remoteassist

B.

purearray remoteassist

C.

purearray remoteassist --connect

Question # 35

What command should the Implementation Engineer run to view NVRAM install and update status?

A.

puredrive list

B.

purearray list

C.

purehw list --all

Question # 36

A customer has a DirectFlash Shelf installed on a FlashArray//X90R4. The 208V rack PDUs are full, but there are five 120V connections available at the top of the rack.

What should the Implementation Engineer understand about powering the DirectFlash Shelf in this scenario?

A.

The shelf can be fully supported by 120V for the duration of its service life.

B.

The shelf can operate temporarily on 120V, but 208/240V should be used as soon as it's available.

C.

The shelf requires at least 180V to operate and will NOT power on with 120V.

D.

The shelf will operate on 120V but with severely degraded NVMe-oF performance.

Question # 37

What is the minimum AC voltage required to operate a FlashArray//X20R4 array?

A.

90

B.

180

C.

220

Question # 38

A customer has a DirectFlash Shelf installed on a FlashArray//X90R4. The 208V rack PDUs are full, but there are five 120V connections available at the top of the rack. What should the Implementation Engineer understand about powering the DirectFlash Shelf in this scenario?

A.

The Shelf requires at least 180V to operate and Will NOT power on With 120V.

B.

The shelf can be fully supported by 120V for the duration of its service life.

C.

The shelf can operate temporarily on 120V, but 208/240V should be used as soon as it's available.

Question # 39

When performing a FlashArray//X50R3 to FlashArray//XL130R5 upgrade, what should the Implementation Engineer do with the 20 DirectFlash Modules from the FlashArray//X50R3?

A.

Insert them into slots 20-39 in the FlashArray//XL130R5 one at a time, allowing parity to reach 100% before inserting the next.

B.

Insert them into slots 0-19 in the FlashArray//XL130R5 one at a time, allowing parity to reach 100% before inserting the next.

C.

Return the drives to Pure Storage after the upgrade script has completed the data migration phase.

D.

Keep the drives installed in the FlashArray//X50R3 and connect it to the FlashArray//XL130R5 as an external DirectFlash Shelf.

Question # 40

What command should the Implementation Engineer run to view NVRAM install and update status?

A.

puredrive list

B.

purehw list --all

C.

purearray list

D.

purefw list