You'll find that our 300-615 exam questions frequently feature detailed scenarios and practical problem-solving exercises that directly mirror industry challenges. Engaging with these 300-615 sample sets allows you to effectively manage your time and pace yourself, giving you the ability to finish any Troubleshooting Cisco Data Center Infrastructure (300-615 DCIT) v1.1 practice test comfortably within the allotted time.

Question # 21

Refer to the exhibit.

A Cisco UCS B-Series Blade Server is configured to boot from a shared storage via an iSCSI network. When a service profile is associated with the blade, the blade fails to attach the LUN. Which action resolves the issue?

A.

Place VLAN 0 on the interface that connects to the storage

B.

Register the blade as an initiator on the storage array

C.

Implement a Layer 3 connection between the blade and the storage

D.

Establish a Layer 2 connection between the blade and the storage

Question # 22

Refer to the exhibit. An engineer troubleshoots an OSPF neighborship problem between Router R2 and Router R10. Which action resolves the problem?

A.

Change area ID on Router R10

B.

Resolve unicast reply from Router R2

C.

Resolve authentication type on Router R10

D.

Change router ID on Router R10

Question # 23

A Fibre Channel interface on a Cisco Nexus 5000 Series Switch receives bit errors, and the switch disables the interface. A temporary workaround must be implemented before the root cause is identified. Which action does an engineer take to prevent this issue from reoccurring?

A.

Verify that the SFPs are supported.

B.

Change the SFP to operate at 4 Gbps instead of 2 Gbps.

C.

Run the shutdown and then no shutdown command on the interface.

D.

Run the switchport ignore bit-errors command on the interface.

Question # 24

Refer to the exhibit. A SAN engineer must enforce the port security configuration database in Fibre Channel fabric that uses Cisco MDS 9000 Switches. Port security is enabled on the VSAN to which the port belongs. However, the rogue host can still log in to the fabric. Which Cisco MDS command resolves the issue?

A.

Option A

B.

Option B

C.

Option C

D.

Option D

Question # 25

An engineer experiences an issue presented with the Cisco ucs system. Which action resolves the issue?

A.

Change the discovery policy backplane speed preference to 4x10G.

B.

Connect the adapter to the fabric interconnects using a breakout cable.

C.

Update the 1/O module firmware on the Cisco UCS chassis.

D.

Reboot the blade server and acknowledge the fault.

Question # 26

An FSM failed during an upgrade with the auto-install feature enabled. The engineer must remove the service pack from the subordinate fabric interconnect (FI) to recover the Fls. Which set of commands resolves the issue?

A.

UCS-A# scope org

UCS-A/org # scope fw-infra-pack default

UCS-A /org/fw-infra-pack # set infra-bundle-version " "

UCS-A/org/fw-infra-pack* # commit-buffer

B.

UCS-A# scope fabric-interconnect b

UCS-A# /fabric-interconnect # remove service-pack

UCS-A# /fabric-interconnect* # commit-buffer

C.

UCS-A# scope org

UCS-A/org # scope fw-infra-pack default

UCS-A /org/fw-infra-pack # set infra-bundle-version

UCS-A# /fabric-interconnect # remove service-pack security

UCS-A# /fabric-interconnect* # commit-buffer

D.

UCS-A# scope fabric-interconnect b

UCS-A# /fabric-interconnect # remove service-pack security

UCS-A# /fabric-interconnect* # commit-buffer

Question # 27

Refer to the exhibit.

An upgrade operation fails with an error displayed. Which action resolve the issue?

A.

Use a different system image

B.

Use a different kickstart image

C.

Allocate extra space on a flash drive to extract a kickstart image

D.

Allocate extra space on a flash drive to extract a system image

Question # 28

An engineer upgrades Cisco UCS firmware from release 3. 1(2) to release 3. 1(3) using Auto Install. Both fabric interconnects go offline during the software upgrade installation and issue multiple F SM retries in the DeployPollActivate stage. Which set of actions resolves the issue?

A.

Fix the rights to 666 with the debug plugin on the primary fabric interconnet Save the current configuration on the running fabric interconnect.

Continue the upgrade on both fabric interconnects.

B.

Enable the management interface monitoring policy on the fabric interconnects. Initiate a configuration backup on both fabric interconnects.

Commit the pending fabric interconnect reboot activity.

C.

Acknowledge the error and reboot the primary fabric interconnect. Clear the default firmware version and upload a new one.

Restart the upgrade process manually.

D.

Clear the startup version of the default infrastructure and server pack. Remove the service pack from the subordinate node.

Upgrade with the Force attribute through Auto Install.

Question # 29

The script fails to convert a JSON variable into a Python dictionary. Which action resolves the issue?

A.

Use a json.dumps(json_output) function

B.

Define a json_output as a YAML object, yaml json_output

C.

Fix the JSON syntax by modifying “attribures” to “attribures”:

D.

Invoke a function yaml.loads(json._output ,decoder_”json”)

Question # 30

Refer to the exhibit.

An engineer fails to load the Cisco Nexus 9000 Series Switch to configuration mode. Which command set resolves the issue?

A.

Loader > boot bootflash:bootflash_sync_list

switch(config)# boot nxos bootflash:nxos.7.0.3.I7.8.bin

switch(config)# copy run start

B.

Loader > boot nxos.7.0.3.I7.8.bin

switch(config)# boot nxos bootflash:bootflash_sync_list

switch(config)# copy run start

C.

Loader > boot nxos.7.0.3.I7.8.bin

switch(config)# boot nxos bootflash:nxos.7.0.3.I7.8.bin

switch(config)# copy run start

D.

Loader > boot nxos.7.0.3.I7.8.bin

switch(config)# boot bootflash:nxos.7.0.3.I7.8.bin

switch(config)# copy run start